Fatal inappropriate ICD shock

被引:37
作者
Veltmann, Christian [1 ]
Borggrefe, Martin [1 ]
Schimpf, Rainer [1 ]
Wolpert, Christian [1 ]
机构
[1] Univ Klinikum Mannheim, Dept Med, D-68167 Mannheim, Germany
关键词
implantable cardioverter defibrillator; proarrhythmia; inappropriate ICD therapy; proarrhythmic ICD shock;
D O I
10.1111/j.1540-8167.2006.00692.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Inappropriate implantable cardioverter defibrillator (ICD) therapy carries a low but relevant risk of ventricular proarrhythmia. In the present case, the extremely rare event of a fatal arrhythmia caused by inappropriate therapy is reported. Dislodgement of the ventricular lead to the level of the tricuspid annulus led to additional sensing of the atrial signal during sinus tachycardia. Spuriously, ventricular fibrillation was sensed and induced inappropriate ICD shocks. The fourth inappropriate shock caused ventricular fibrillation, which was subsequently undersensed by the dislodged lead due to low ventricular amplitudes. The ICD started antibradycardic pacing during ventricular fibrillation. After initial successful resuscitation, the patient died I week later due to severe hypoxic brain damage. Although not preventable in the present case, it underlines the necessity of immediate interrogation of the ICD after ICD therapy and deactivation of the ICD in the setting of a dislodged endocardial lead and intensive care monitoring of the patient until revision.
引用
收藏
页码:326 / 328
页数:3
相关论文
共 17 条
[1]   Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients [J].
Alter, P ;
Waldhans, S ;
Plachta, E ;
Moosdorf, R ;
Grimm, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09) :926-932
[2]   The 1+1 trial -: A prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias [J].
Bänsch, D ;
Steffgen, F ;
Grönefeld, G ;
Wolpert, C ;
Böcker, D ;
Mletzko, RU ;
Schöls, W ;
Seidl, K ;
Piel, M ;
Ouyang, F ;
Hohnloser, SH ;
Kuck, KH .
CIRCULATION, 2004, 110 (09) :1022-1029
[3]   Patient alert in implantable cardioverter defibrillators: Toy or tool? [J].
Becker, R ;
Ruf-Richter, J ;
Senges-Becker, JC ;
Bauer, A ;
Weretka, S ;
Voss, F ;
Katus, HA ;
Schoels, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :95-98
[4]   Automatic impedance monitoring and patient alert feature in implantable cardioverter defibrillators: Being alert for the unexpected! [J].
Duru, F ;
Luechinger, R ;
Scharf, C ;
Brunckhorst, C .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) :444-448
[5]   Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure [J].
Gunderson, BD ;
Gillberg, JM ;
Wood, MA ;
Vijayaraman, P ;
Shepard, RK ;
Elenbogen, KA .
HEART RHYTHM, 2006, 3 (02) :155-162
[6]   Automatic identification of clinical lead dysfunctions [J].
Gunderson, BD ;
Patel, AS ;
Bounds, CA ;
Ellenbogen, KA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S63-S67
[7]   An algorithm to predict implantable cardioverter-defibrillator lead failure [J].
Gunderson, BD ;
Patel, AS ;
Bounds, CA ;
Shepard, RK ;
Wood, MA ;
Ellenbogen, KA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (09) :1898-1902
[8]   Inappropriate detection of supraventricular arrhythmias by implantable dual chamber defibrillators: A comparison of four different algorithms [J].
Hintringer, F ;
Schwarzacher, S ;
Eibl, G ;
Pachinger, O .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (05) :835-841
[9]   Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia [J].
Kouakam, C ;
Kacet, S ;
Hazard, JR ;
Ferraci, A ;
Mansour, H ;
Defaye, P ;
Davy, JM ;
Lambiez, M .
EUROPACE, 2004, 6 (01) :32-42
[10]  
Kron Jack, 2003, Card Electrophysiol Rev, V7, P473, DOI 10.1023/B:CEPR.0000023163.67758.b1