Automatic impedance monitoring and patient alert feature in implantable cardioverter defibrillators: Being alert for the unexpected!

被引:8
作者
Duru, F
Luechinger, R
Scharf, C
Brunckhorst, C
机构
[1] Univ Zurich Hosp, Div Cardiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] ETH, Inst Biomed Engn, Zurich, Switzerland
关键词
implantable cardioverter defibrillator; patient alert; impedance; high voltage; safety;
D O I
10.1046/j.1540-8167.2005.40592.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patient Alert in ICDs. Recent advances in implantable cardioverter defibrillator (ICD) technology have enabled implementation of an automatic monitoring feature in ICDs that provides daily measurements of several technical parameters such as battery status, pacing, and high-voltage impedance. The system alerts the patient with an audible alarm to contact the physician in case the measured parameters are not within normal limits. Early detection of intermittent and potentially serious complications justifies routine use of this feature. This report describes a patient with an ICD who died suddenly due to ventricular fibrillation, which was not appropriately treated by the device. The cause of device malfunction was most likely an intermittent lead fracture that was not detected by the automatic impedance monitoring and alert feature of this device. Based on these data, potential benefits and theoretical pitfalls of automatic impedance monitoring and alert features are discussed.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 13 条
[1]   Patient alert in implantable cardioverter defibrillators: Toy or tool? [J].
Becker, R ;
Ruf-Richter, J ;
Senges-Becker, JC ;
Bauer, A ;
Weretka, S ;
Voss, F ;
Katus, HA ;
Schoels, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :95-98
[2]   Transvenous defibrillation leads: High incidence of failure during long-term follow-up [J].
Dorwarth, U ;
Frey, B ;
Dugas, M ;
Matis, T ;
Fiek, M ;
Schmoeckel, M ;
Remp, T ;
Durchlaub, I ;
Gerth, A ;
Steinbeck, G ;
Hoffmann, E .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) :38-43
[3]   Lead fracture in cephalic versus subclavian approach with transvenous implantable cardioverter defibrillator systems [J].
Gallik, DM ;
BenZur, UM ;
Gross, JN ;
Furman, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (07) :1089-1094
[4]   INCIDENCE OF ICD LEAD RELATED COMPLICATIONS DURING LONG-TERM FOLLOW-UP - COMPARISON OF EPICARDIAL AND ENDOCARDIAL ELECTRODE SYSTEMS [J].
KORTE, T ;
JUNG, W ;
SPEHL, S ;
WOLPERT, C ;
MOOSDORF, R ;
MANZ, M ;
LUDERITZ, B .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (11) :2053-2061
[5]   Implantable defibrillators impedance measurement using pacing pulses versus shock delivery with intact and modified high voltage lead system [J].
Mehdirad, AA ;
Stohr, EC ;
Love, CJ ;
Nelson, SD ;
Schaal, SF .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (03) :437-441
[6]  
Schulte B, 1998, Z KARDIOL, V87, P630, DOI 10.1007/s003920050222
[7]  
Sheth N, 2002, CAN J CARDIOL, V18, P430
[8]   SENSING PACING LEAD COMPLICATIONS WITH A NEWER GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - WORLDWIDE EXPERIENCE FROM THE GUARDIAN-ATP-4210 CLINICAL-TRIAL [J].
STAMBLER, BS ;
WOOD, MA ;
DAMIANO, RJ ;
GREENWAY, PS ;
SMUTKA, ML ;
ELLENBOGEN, KA ;
BATSFORD, W ;
BAUERNFEIND, R ;
BECKMAN, K ;
BROWNSTEIN, S ;
CASTLE, L ;
DEERING, T ;
ELLENBOGEN, K ;
ESTES, NAM ;
FRANKLIN, J ;
FREIHLING, T ;
HAISTY, K ;
KEHOE, R ;
LOVE, C ;
LUCERI, R ;
NACCARELLI, G ;
PACIFICO, A ;
PARSONNET, V ;
PETROPOULOS, T ;
SAKSENA, S ;
SHARMA, A ;
SINGER, I ;
VENDITTI, F ;
WALTER, P ;
ZIPES, D ;
DAVIS, MJ ;
HELLESTRAND, K ;
KUCHAR, D ;
POWELL, A ;
STAFFORD, W ;
UTHER, J ;
VOHRA, J ;
DORIAN, P ;
GULAMHUSEIN, S ;
KERR, CR ;
ROSENGARTEN, M ;
ROY, D ;
TANG, ASL ;
WILLIAMS, W ;
YEE, R ;
MOLLER, M ;
THOMSEN, PEB ;
ALIOT, E ;
LECLERQ, JF ;
LEMAREC, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (01) :123-132
[9]   Early detection of lead fracture by painless high voltage lead impedance measurement in a transvenous ICD lead system [J].
Stevens, J ;
Buchwald, B ;
Krieglstein, H ;
Unterberg, C .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (01) :269-272
[10]   Subthreshold test pulses versus low energy shock delivery to estimate high energy lead impedance in implanted cardioverter defibrillator patients [J].
Vollmann, D ;
Luethje, L ;
Zenker, D ;
Domhof, S ;
Unterberg, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :457-460