Feasibility and optimization of aortic valve planimetry with MDCT

被引:25
作者
Abbara, Suhny [1 ]
Pena, Antonio J. [1 ]
Maurovich-Horvat, Paul [1 ]
Butler, Javed [1 ]
Sosnovik, David E. [1 ]
Lembcke, Alexander [1 ]
Cury, Ricardo C. [1 ]
Hoffmann, Udo [1 ]
Ferencik, Maros [1 ]
Brady, Thomas J. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
aorta; aortic valve; cardiac imaging; coronary artery disease; heart disease; MDCT; planimetry;
D O I
10.2214/AJR.06.0232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. The aortic valve can be assessed using MDCT; however, measurements of the aortic opening area vary with the cardiac cycle. In this study, we sought to assess the optimal timing for measuring the area of the aortic opening with MDCT. MATERIALS AND METHODS. Retrospectively gated MDCT was performed in 57 patients with the following parameters: gantry rotation time, 420 milliseconds; tube voltage, 120 kV; tube current, 550 mAs with tube current modulation; and slice collimation, 16 x 0.75 mm. From 72 to 100 mL of contrast agent ( 320 g/mL(3)) was injected IV at 4 - 5 mL/s. High-resolution data sets were obtained for planimetry at phase starts of 0, 50, 100, 150, and 200 milliseconds after the R wave peak and were assessed for aortic opening area and the presence of artifacts. RESULTS. In 41% of patients, the cardiac phase with the largest aortic opening area was at 50 milliseconds after the R wave peak. The area of the aortic opening measured at 0 milliseconds after the R peak was 2.7 +/- 0.8 cm(2) ( mean +/- SD); at 50 milliseconds, 2.9 +/- 0.2 cm(2); at 100 milliseconds, 2.9 +/- 0.7 cm(2); at 150 milliseconds, 2.8 +/- 0.7 cm(2); and at 200 milliseconds, 2.4 +/- 0.8 cm(2). The image quality was best at 50 milliseconds after the R peak in 42% of patients, 100 milliseconds in 29%, 150 milliseconds in 20%, 0 milliseconds in 7%, and 200 milliseconds in 2%. The aortic valve appeared closed in three patients at 0 milliseconds and in four patients at 200 milliseconds. Fewer artifacts were present in the midsystolic phases (i.e., 50 - 150 milliseconds) ("double-leaflet" artifact, 5 - 13%; "incomplete contour" artifact, 20 - 26%) than in the early ( 0 milliseconds) and late ( 200 milliseconds) systolic phases (double-leaflet artifact, 38% and 43% of patients; incomplete contour artifact, 76% and 73%, respectively). CONCLUSION. Aortic valve planimetry is best performed at phase starts of 50 - 100 milliseconds after the R peak because the area of the aortic opening is widest and image quality is best at that phase.
引用
收藏
页码:356 / 360
页数:5
相关论文
共 11 条
[1]
Imaging of coronary atherosclerosis using computed tomography: Current status and future directions [J].
Achenbach S. ;
Daniel W.G. .
Current Atherosclerosis Reports, 2004, 6 (3) :213-218
[2]
Aortic stenosis. [J].
Carabello, BA .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (09) :677-682
[4]
Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[5]
Magnetic resonance to assess the aortic valve area in aortic stenosis - How does it compare to current diagnostic standards? [J].
John, AS ;
Dill, T ;
Brandt, RR ;
Rau, M ;
Ricken, W ;
Bachmann, G ;
Hamm, CW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) :519-526
[6]
Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques [J].
Kupfahl, C ;
Honold, M ;
Meinhardt, G ;
Vogelsberg, H ;
Wagner, A ;
Mahrholdt, H ;
Sechtem, U .
HEART, 2004, 90 (08) :893-901
[7]
Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[8]
Transesophageal echocardiographic evaluation of native aortic valve area: Utility of the double-envelope technique [J].
Maslow, AD ;
Mashikian, J ;
Haering, JM ;
Heindel, S ;
Douglas, P ;
Levine, R .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (03) :293-299
[9]
Role of echocardiography in the diagnosis and treatment of patients with aortic stenosis [J].
Mochizuki, Y ;
Pandian, NG .
CURRENT OPINION IN CARDIOLOGY, 2003, 18 (05) :327-333
[10]
Aortic stenosis: The role of transesophageal echocardiography [J].
Naqvi, TZ ;
Siegel, RJ .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (07) :677-688