Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniques

被引:107
作者
Kupfahl, C [1 ]
Honold, M [1 ]
Meinhardt, G [1 ]
Vogelsberg, H [1 ]
Wagner, A [1 ]
Mahrholdt, H [1 ]
Sechtem, U [1 ]
机构
[1] Robert Bosch Med Ctr, Dept Cardiol & Pulmol, Stuttgart, Germany
关键词
D O I
10.1136/hrt.2003.022376
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate whether direct planimetry of aortic valve area (AVA) by cardiac magnetic resonance (CMR) imaging is a reliable tool for determining the severity of aortic stenosis compared with transthoracic echocardiography (TTE), transoesophageal echocardiography (TOE), and cardiac catheterisation. Methods: 44 symptomatic patients with severe aortic stenosis were studied. By cardiac catheterisation AVA was calculated by the Gorlin equation. AVA was measured with CMR from steady state free precession (true fast imaging with steady state precession) by planimetry. AVA was also determined from TOE images by planimetry and from TTE images by the continuity equation. Results: Bland-Altman analysis evaluating intraobserver and interobserver variability showed a very small bias for both (-0.016 and 0.019, respectively; n=20). Bias and limits of agreement between CMR and TTE were 0.05 (-0.35, 0.44) cm(2) (n=37), between CMR and TOE 0.02 (-0.39, 0.42) cm(2) (n=32), and between CMR and cardiac catheterisation 0.09 (-0.30, 0.47) cm(2) (n=36). The sensitivity and specificity of CMR to detect AVA less than or equal to0.80 cm(2) measured by cardiac catheterisation was 78% and 89%, of TOE 70% and 70%, and of TTE 74% and 67%, respectively. Conclusion: CMR planimetry is highly reliable and reproducible. Further, CMR planimetry had the best sensitivity and specificity of all non-invasive methods for detecting severe aortic stenosis in comparison with cardiac catheterisation. Therefore, CMR planimetry of AVA with steady state free precession is a new powerful diagnostic tool, particularly for patients with uncertain or discrepant findings by other modalities.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 41 条
[1]   Magnetic resonance imaging safety: Implications for cardiovascular patients [J].
Ahmed, S ;
Shellock, FG .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (03) :171-182
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]   ACCURACY OF AORTIC-STENOSIS SEVERITY ASSESSMENT BY DOPPLER-ECHOCARDIOGRAPHY - IMPORTANCE OF IMAGE QUALITY [J].
BARTUNEK, J ;
DEBACQUER, D ;
RODRIGUES, AC ;
DEBRUYNE, B .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1995, 11 (02) :97-104
[4]   Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis [J].
Bernard, Y ;
Meneveau, N ;
Vuillemenot, A ;
Magnin, D ;
Anguenot, T ;
Schiele, F ;
Bassand, JP .
HEART, 1997, 78 (01) :68-73
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle [J].
Bloomer, TN ;
Plein, S ;
Radjenovic, A ;
Higgins, DM ;
Jones, TR ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :685-692
[7]  
Bonow R O, 1998, J Heart Valve Dis, V7, P672
[8]  
Braunwald E., 2001, HEART DIS
[9]   HYDRAULIC ESTIMATION OF STENOTIC ORIFICE AREA - A CORRECTION OF THE GORLIN FORMULA [J].
CANNON, SR ;
RICHARDS, KL ;
CRAWFORD, M .
CIRCULATION, 1985, 71 (06) :1170-1178
[10]   INADEQUACY OF THE GORLIN FORMULA FOR PREDICTING PROSTHETIC VALVE AREA [J].
CANNON, SR ;
RICHARDS, KL ;
CRAWFORD, MH ;
FOLLAND, ED ;
PIERPONT, G ;
SETHI, GK ;
HAMMERMEISTER, KE .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (01) :113-116