A critical analysis of stress shielding evaluation of hip prostheses

被引:114
作者
Cristofolini, L [1 ]
机构
[1] Rizzoli Orthopaed Inst, Lab Biomat Technol, Bologna, Italy
[2] Univ Bologna, Fac Engn, Bologna, Italy
关键词
femur; hip stems; loading; strain measurement; methodology; errors;
D O I
10.1615/CritRevBiomedEng.v25.i4-5.30
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro evaluation of the load transfer of hip prostheses has been performed in recent years for the purpose of understanding the stress shielding phenomena. Over 200 papers were reviewed to determine if a standard exists to evaluate and compare the performance of hip stems. Surprisingly, it was found that little agreement exists in the testing protocol. This makes it very difficult to compare the results reported in different investigations. In several cases very incomplete data are reported about the testing conditions, thus making it impossible to compare the results. This article focuses on: (1) how the loading conditions should be chosen based on physiological loading in a way to give a reproducible setup; (2) how the femur should be constrained; (3) how to generate the same system of loads in the intact and the implanted femur; (4) how to define a reference system: (5) how the specimen type and sample size are chosen. (6) the advantages and limitations of the different strain measurement techniques; (7) how the testing parameters have been chosen in the literature; and (8) how the accuracy of the results has been reported in the literature.
引用
收藏
页码:409 / 483
页数:75
相关论文
共 281 条
[91]   RELEVANCE OF OSTEOTOMY AND IMPLANT CHARACTERISTICS IN INTER- AND SUBTROCHANTERIC OSTEOTOMIES - EXPERIMENTAL EXAMINATION UNDER ALTERNATING AND STATIC LOAD AFTER STABILIZATION WITH DIFFERENT DEVICES INCLUDING GAMMA-NAIL OSTEOSYNTHESIS [J].
FRIEDL, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1993, 113 (01) :5-11
[92]  
FULGHUM CS, 1991, 37 ANN M ORTH RES SO, P104
[93]  
Fung Y. C., 1980, BIOMECHANICS MECH PR, P383
[94]   A CRITICAL-REVIEW OF THE BIOMECHANICAL STRESS-ANALYSIS OF THE HUMAN FEMUR [J].
GDOUTOS, EE ;
RAFTOPOULOS, DD ;
BARIL, JD .
BIOMATERIALS, 1982, 3 (01) :2-8
[95]  
GLITSCH U, 1993, 14 ISB C, P492
[96]  
HALLETT JP, 1992, P I MECH ENG H, V206, P39
[97]   INITIAL STABILITY OF UNCEMENTED HIP STEMS - AN IN-VITRO PROTOCOL TO MEASURE TORSIONAL INTERFACE MOTION [J].
HARMAN, MK ;
TONI, A ;
CRISTOFOLINI, L ;
VICECONTI, M .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (03) :163-171
[98]   AN ANALYTICAL AND NUMERICAL STUDY OF THE STABILITY OF BONE REMODELING THEORIES - DEPENDENCE ON MICROSTRUCTURAL STIMULUS [J].
HARRIGAN, TP ;
HAMILTON, JJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (05) :477-488
[99]   A FINITE-ELEMENT STUDY OF THE EFFECT OF DIAMETRAL INTERFACE GAPS ON THE CONTACT AREAS AND PRESSURES IN UNCEMENTED CYLINDRICAL FEMORAL TOTAL HIP COMPONENTS [J].
HARRIGAN, TP ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1991, 24 (01) :87-91
[100]  
HARRIS WH, 1992, CLIN ORTHOP RELAT R, V274, P120