Porous polymer monolith assisted electrospray

被引:50
作者
Koerner, T [1 ]
Turck, K [1 ]
Brown, L [1 ]
Oleschuk, RD [1 ]
机构
[1] Queens Univ, Dept Chem, Kingston, ON K7L 3N6, Canada
关键词
D O I
10.1021/ac049438y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coupling low-flow analytical separation instrumentation such as capillary electrophoresis, capillary electrochromatography, nano-HPLC, and microfluidic-based devices with electrospray ionization mass spectrometry has yielded powerful analytical tools. However, conventional coupling methodologies such as nanospray suffer from limitations including poor conductive coating robustness, constant clogging, complicated fabrication processes, and incompatibility with large flow rate regimes. This study demonstrates that robust nanospray emitters can be fabricated through the formation and utilization of a porous polymer monolith (PPM) at the end of a fused-silica capillary. Stable electrosprays can be produced from capillaries (75-100-mum i.d.) at a variety of flow rates (50-1000nL/min) without the need to taper the capillaries by etching or pulling. The PPM is photopatterned to be present only near the capillary exit aperture using conditions that generate pore sizes similar to those seen with nanospray tips. The porous nature of the PPM aids in developing a stable electrospray generating a single clearly visible Taylor cone at relatively high flow rates while at low flow rates (<100nL/min) a mist, presumably from multiple small Taylor cones, develops. The hydrophobic nature of the PPM should limit problems with band broadening associated with droplet spreading at the capillary exit, while the multiple flow paths inherent in the PPM minimize clogging problems associated with conventional nanospray emitters. Total ion current traces for a constant infusion of standard PPG and cytochrome c solutions are very stable with deviations ranging from only 3 to 8%. The PPM-assisted electrospray produces mass spectra with excellent signal-to-noise ratios from only a few femtomoles of material.
引用
收藏
页码:6456 / 6460
页数:5
相关论文
共 26 条
[1]   High-throughput global peptide proteomic analysis by combining stable isotope amino acid labeling and data-dependent multiplexed-MS/MS [J].
Berger, SJ ;
Lee, SW ;
Anderson, GA ;
Pasa-Tolic, L ;
Tolic, N ;
Shen, YF ;
Zhao, R ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :4994-5000
[2]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[3]   Sample filtration, concentration, and separation integrated on microfluidic devices [J].
Broyles, BS ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2761-2767
[4]   Development of new methodologies for the mass spectrometry study of bioorganic macromolecules [J].
Cristoni, S ;
Bernardi, LR .
MASS SPECTROMETRY REVIEWS, 2003, 22 (06) :369-406
[5]   A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES [J].
DAVIS, MT ;
STAHL, DC ;
HEFTA, SA ;
LEE, TD .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4549-4556
[6]   Proteomics in 2002: A year of technical development and wide-ranging applications [J].
Figeys, D .
ANALYTICAL CHEMISTRY, 2003, 75 (12) :2891-2905
[7]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160
[8]   Interfaces for coupled liquid-phase separation/mass spectrometry techniques.: An update on recent developments [J].
Gelpí, E .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (03) :241-253
[9]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[10]   Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry [J].
Hopfgartner, G ;
Bourgogne, E .
MASS SPECTROMETRY REVIEWS, 2003, 22 (03) :195-214