Newly synthesized poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate)-based electrode designs for phenol biosensors

被引:11
作者
Ozoner, Seyda Korkut [1 ]
Erhan, Elif [1 ]
Yilmaz, Faruk [2 ]
Celik, Asuman [2 ]
Keskinler, Bulent [1 ]
机构
[1] Gebze Inst Technol, Dept Environm Engn, TR-41400 Gebze, Kocaeli, Turkey
[2] Gebze Inst Technol, Dept Chem, TR-41400 Gebze, Kocaeli, Turkey
关键词
Phenol biosensor; Horseradish peroxidase; Poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate); Polypyrrole; Thiophene; FLOW-INJECTION DETERMINATION; LAYERED DOUBLE HYDROXIDES; AMPEROMETRIC BIOSENSOR; ELECTROCHEMICAL BIOSENSOR; HORSERADISH-PEROXIDASE; CONDUCTING COPOLYMERS; 3-METHYLTHIENYL METHACRYLATE; ELECTROCHROMIC PROPERTIES; 3-THIOPHENE CARBOXYLATE; GLYCIDYL METHACRYLATE;
D O I
10.1016/j.talanta.2009.11.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A newly synthesized poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate) [poly(GMA-co-MTM)] was designed to fabricate various HRP electrodes for detection of phenol derivatives. The results showed that the poly(GMA-co-MTM)/polypyrrole composite film microarchitecture provided a good electroactivity as a result of pyrrole and thiophene interaction, and provided chemical bonds for enzyme immobilization via the epoxy groups of poly(GMA-co-MTM). The glassy carbon-based working electrode displayed significantly higher performance for the same composite film configuration comparing to the gold-based working electrode. Poly(GMA-co-MTM)/polypyrrole/HRP coated glassy carbon electrode exhibited a fast response less than 3s, a high sensitivity (200 nA mu M for hydroquinone), a good operational stability (%RSD values ranged between 2 and 5.1 for all phenolics). a long-term stability (retained about 80% of initial activity at the end of 40th day) and a low detection limit ranging between 0.13 and 1.87 mu M for the tested. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 80 条
[1]   Synthesis and characterization of a pyrrole-alginate conjugate and its application in a biosensor construction [J].
Abu-Rabeah, K ;
Polyak, B ;
Ionescu, RE ;
Cosnier, S ;
Marks, RS .
BIOMACROMOLECULES, 2005, 6 (06) :3313-3318
[2]  
ANNI H, 1992, METAL IONS BIOL SYST
[3]  
Barisci JN, 1996, TRENDS POLYM SCI, V4, P307
[4]  
BECK F, 1992, J COATING TECHNOL, V64, P59
[5]  
Bilitewski U., 2000, Biosensors in Environmental Monitoring
[6]   BIOELECTROCATALYSIS BY IMMOBILIZED PEROXIDASE - THE REACTION-MECHANISM AND THE POSSIBILITY OF ELECTROANALYTICAL DETECTION OF BOTH INHIBITORS AND ACTIVATORS OF ENZYME [J].
BOGDANOVSKAYA, VA ;
FRIDMAN, VA ;
TARASEVICH, MR ;
SCHELLER, F .
ANALYTICAL LETTERS, 1994, 27 (15) :2823-2847
[7]   Synthesis, characterization and electrochromic properties of conducting copolymers of 3-[(3-thienylcarbonyl)oxy]-2,2-bis{[(3-thienylcarbonyl)oxy]}propyl 3-thiophene carboxylate with thiophene and pyrrole [J].
Bulut, U ;
Yilmaz, F ;
Yagci, Y ;
Toppare, L .
REACTIVE & FUNCTIONAL POLYMERS, 2004, 61 (01) :63-70
[8]   Synthesis, characterization, and electrochromic properties of conducting copolymers of 2-[(3-thienylcarbonyl)oxy]ethyl 3-thiophene carboxylate with thiophene and pyrrole [J].
Bulut, U ;
Alkan, S ;
Yilmaz, F ;
Yagci, Y ;
Toppare, L .
JOURNAL OF MACROMOLECULAR SCIENCE-PURE AND APPLIED CHEMISTRY, 2004, A41 (08) :937-947
[9]   Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors [J].
Campuzano, S ;
Serra, B ;
Pedrero, M ;
de Villena, FJM ;
Pingarrón, JM .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :187-197
[10]   Conducting copolymers of random and block copolymers of electroactive and liquid crystalline monomers with pyrrole and thiophene [J].
Camurlu, Pinar ;
Toppare, Levent ;
Yilmaz, Faruk ;
Yagci, Yusuf ;
Galli, Giancarlo .
JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY, 2007, 44 (03) :265-270