Two near-infrared spectroscopy (NIRS) devices were compared with regard to their responses to changes in cerebral hemoglobin oxygenation induced by hypoxia and hypercapnia in five healthy volunteers. Sensors belonging to each NIRS device were placed on opposite sides of the volunteer's forehead. The INVOS3100A device, approved by the United States Food and Drug Administration, records the percentage of oxyhemoglobin (HbO(2)) saturation and the investigational NIRO500 device records absolute changes in HbO(2), deoxyhemoglobin, and total hemoglobin in micromolar concentrations referenced to an arbitrary baseline. The volunteers breathed separate mixtures of 7% CO2 in O-2 and 10% O-2 for 5 minutes in random order. Arterial blood pressure, end-tidal CO2 (ETCO2), arterial O-2 saturation, and electrocardiographic data were continuously monitored. Hypercapnia increased (p < 0.01) ETCO2 from 42 +/- 2 to 56 +/- 3 mm Hg (mean +/- standard deviation), resulting in a 7.3 +/- 0.2% increase (p < 0.005) in cerebral HbO(2) saturation detected by the INVOS3100A device and an 11.6 +/- 3 mu M increase (p < 0.0008) in HbO(2) detected by the NIRO500. Hypoxia decreased (p < 0.01) arterial HbO(2) saturation from 98 +/- 1 to 87 +/- 3%, causing a 5.1 +/- 1.2% decrease (p < 0.01) in the percentage of HbO(2) saturation detected by the INVOS3100A device and a 9.7 +/- 6.3 mu M decrease in HbO(2) detected by the NIRO500. The responses of the NIRO500 and the INVOS3100A instruments to changes in cerebral oxygenation resulting from hypercapnia and hypoxia were generally similar; however, responses tended to be greater when recorded by the NIRO500 device, perhaps because, unlike the INVOS3100A device, the NIRO500 does not correct for skin and bone contamination.
引用
收藏
页码:351 / 354
页数:4
相关论文
共 28 条
[1]   Near-infrared spectroscopy (NIRS) measurements of cerebral oximetry in the neurovascular ICU [J].
Armonda, RA ;
McGee, B ;
Veznadaraglu, E ;
Rosenwasser, RH ;
Jefferson, RH .
CRITICAL CARE MEDICINE, 1999, 27 (12) :A72-A72
[2]   Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy [J].
Cho, H ;
Nemoto, EM ;
Yonas, H ;
Balzer, J ;
Sclabassi, RJ .
JOURNAL OF NEUROSURGERY, 1998, 89 (04) :533-538
[3]   Cerebral oxygenation during paediatric cardiac surgery: identification of vulnerable periods using near infrared spectroscopy [J].
Daubeney, PEF ;
Smith, DC ;
Pilkington, SN ;
Lamb, RK ;
Monro, JL ;
Tsang, VT ;
Livesey, SA ;
Webber, SA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (04) :370-377
[4]   Failure of the INVOS 3100 cerebral oximeter to detect complete absence of cerebral blood flow [J].
Gomersall, CD ;
Joynt, GM ;
Gin, T ;
Freebairn, RC ;
Stewart, IET .
CRITICAL CARE MEDICINE, 1997, 25 (07) :1252-1254
[5]   A comparison of the monitors INVOS3100 and NIRO500 in detecting changes in cerebral oxygenation [J].
Grubhofer, G ;
Tonninger, W ;
Keznicki, P ;
Skyllouriotis, P ;
Ehrlich, M ;
Hiesmayr, M ;
Lassnigg, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (04) :470-475
[6]   EFFECT OF ALTERATIONS IN ARTERIAL CARBON DIOXIDE TENSION ON BLOOD FLOW THROUGH CEREBRAL CORTEX AT NORMAL AND LOW ARTERIAL BLOOD PRESSURES [J].
HARPER, AM ;
GLASS, HI .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1965, 28 (05) :449-+
[7]   Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia [J].
Henson, LC ;
Calalang, C ;
Temp, JA ;
Ward, DS .
ANESTHESIOLOGY, 1998, 88 (01) :58-65
[8]  
HOFFMAN J, 1986, ADV EXP MED BIOL, V191, P119
[9]   NONINVASIVE CEREBRAL OPTICAL SPECTROSCOPY - DEPTH-RESOLVED MEASUREMENTS OF CEREBRAL HEMODYNAMICS USING INDOCYANINE GREEN [J].
HONGO, K ;
KOBAYASHI, S ;
OKUDERA, H ;
HOKAMA, M ;
NAKAGAWA, F .
NEUROLOGICAL RESEARCH, 1995, 17 (02) :89-93
[10]   Microcirculatory oxygenation and shunting in sepsis and shock [J].
Ince, C ;
Sinaasappel, M .
CRITICAL CARE MEDICINE, 1999, 27 (07) :1369-1377