Pressurized hot water extraction coupled on line with LC-GC:: Determination of polyaromatic hydrocarbons in sediment

被引:59
作者
Hyötyläinen, T [1 ]
Andersson, T [1 ]
Hartonen, K [1 ]
Kuosmanen, K [1 ]
Riekkola, ML [1 ]
机构
[1] Univ Helsinki, Dept Chem, Analyt Chem Lab, FIN-00014 Helsinki, Finland
关键词
D O I
10.1021/ac000282l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pressurized hot water extraction (PHWE) was directly combined with a LC-GC system for the determination of polyaromatic hydrocarbons (PAHs) in sediment. The sediment sample was first extracted with pressurized hot water, and the analytes were adsorbed into a solid-phase trap. The trap also functioned as a LC column, which removed most of the interfering matrix components. The 780-mu L LC fraction containing the analytes was directly transferred to the GC using an on-column interface. The whole PHWE-LC-GC analysis took place in a closed system, and no sample pretreatment was required. The sensitivity of the method was excellent due to the efficient concentration in the LC-GC system, Sensitivity was similar to 800 times better than in traditional systems. In addition, only a small amount of sample (10 mg) was required for the analysis, The PHWE-LC-GC method proved to be linear in the concentration range of 0.01-2 mu g/g, the limits of quantification were below 0.01 mu g/g for all the analytes, and the relative standard deviations were between 3 and 28%, LC cleanup and the improved sensitivity made detection with FID sufficient for the determination of analytes, The results were comparable to those obtained in an interlaboratory comparison study as well as to the results obtained with off-line SFE-GC-MS.
引用
收藏
页码:3070 / 3076
页数:7
相关论文
共 17 条
[1]  
BOWADT S, 1999, 141998 VKI I WAT ENV
[2]  
BUDOD MD, 1993, ANAL CHEM, V65, P1497
[3]   Supercritical fluid extraction of polycyclic aromatic hydrocarbons (PAHs) in marine sediments and GC-MS analysis. [J].
Cardellicchio, N ;
Cavalli, S ;
Ragone, P .
POLYCYCLIC AROMATIC COMPOUNDS, 1996, 9 (1-4) :365-372
[4]   On-line sample treatment - Capillary gas chromatography [J].
Goosens, EC ;
de Jong, D ;
de Jong, GJ ;
Brinkman, UAT .
CHROMATOGRAPHIA, 1998, 47 (5-6) :313-345
[5]   Extraction of polychlorinated biphenyls with water under subcritical conditions [J].
Hartonen, K ;
Inkala, K ;
Kangas, M ;
Riekkola, ML .
JOURNAL OF CHROMATOGRAPHY A, 1997, 785 (1-2) :219-226
[6]  
HARTONEN K, UNPUB
[7]   EXTRACTION OF ORGANIC POLLUTANTS FROM ENVIRONMENTAL SOLIDS WITH SUBCRITICAL AND SUPERCRITICAL WATER [J].
HAWTHORNE, SB ;
YANG, Y ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2912-2920
[8]  
Hyotylainen T, 1997, HRC-J HIGH RES CHROM, V20, P410, DOI 10.1002/jhrc.1240200803
[9]   KINETIC-STUDY OF SUPERCRITICAL-FLUID EXTRACTION OF ORGANIC CONTAMINANTS FROM HETEROGENEOUS ENVIRONMENTAL-SAMPLES WITH CARBON-DIOXIDE AND ELEVATED-TEMPERATURES [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1727-1736
[10]  
Lewis AC, 1997, HRC-J HIGH RES CHROM, V20, P109