Tricuspid valve replacement with the St. Jude Medical valve: 19 years of experience

被引:24
作者
Kawano, H [1 ]
Oda, T [1 ]
Fukunaga, S [1 ]
Tayama, E [1 ]
Kawara, T [1 ]
Oryoji, A [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 830, Japan
关键词
tricuspid valve replacement; St. Jude medical;
D O I
10.1016/S1010-7940(00)00570-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. Methods. This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). Results: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. Conclusions: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 18 条
  • [1] TRICUSPID-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE
    AOYAGI, S
    NISHI, Y
    KAWARA, T
    ORYOJI, A
    HARA, H
    KOSUGA, K
    OHISHI, K
    [J]. SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1994, 24 (01): : 6 - 12
  • [2] LONG-TERM RESULTS OF VALVE-REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE
    AOYAGI, S
    ORYOJI, A
    NISHI, Y
    TANAKA, K
    KOSUGA, K
    OISHI, K
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (06) : 1021 - 1029
  • [3] LONG-TERM RESULTS OF VALVE-REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS
    BAUDET, EM
    PUEL, V
    MCBRIDE, JT
    GRIMAUD, JP
    ROQUES, F
    CLERC, F
    ROQUES, X
    LABORDE, N
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (05) : 858 - 870
  • [4] BOSKOVIC D, 1986, J THORAC CARDIOV SUR, V91, P1
  • [5] Guidelines for reporting morbidity and mortality after cardiac valvular operations
    Edmunds, LH
    Clark, RE
    Cohn, LH
    Grunkemeier, GL
    Miller, DC
    Weisel, RD
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (09) : 812 - 816
  • [6] IN-HOSPITAL AND LONG-TERM OUTCOME AFTER PORCINE TRICUSPID-VALVE REPLACEMENT
    GLOWER, DD
    WHITE, WD
    SMITH, LR
    YOUNG, WG
    OLDHAM, HN
    WOLFE, WG
    LOWE, JE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (05) : 877 - 884
  • [7] Is a bioprosthesis preferable in tricuspid valve replacement?
    Hayashi, J
    Saito, A
    Yamamoto, K
    Watanabe, H
    Ohzeki, H
    Eguchi, S
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1996, 44 (05) : 230 - 233
  • [8] EXCELLENT DURABILITY OF THE HANCOCK PORCINE BIOPROSTHESIS IN THE TRICUSPID POSITION
    KAWACHI, Y
    TOMINAGA, R
    HISAHARA, M
    NAKASHIMA, A
    YASUI, H
    TOKUNAGA, K
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (06) : 1561 - 1566
  • [9] TRICUSPID-VALVE REPLACEMENT WITH THE BILEAFLET ST-JUDE MEDICAL VALVE PROSTHESIS
    NAKANO, K
    KOYANAGI, H
    HASHIMOTO, A
    OHTSUKA, G
    NOJIRI, C
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (05) : 888 - 892
  • [10] Ten-year experience with the Carpentier-Edwards pericardial xenograft in the tricuspid position
    Nakano, K
    Eishi, K
    Kosakai, Y
    Isobe, F
    Sasako, Y
    Nagata, S
    Ueda, H
    Kito, Y
    Kawashima, Y
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03) : 605 - 612