Radiographic assessment of anterior titanium mesh cages

被引:69
作者
Eck, KR [1 ]
Lenke, LG [1 ]
Bridwell, KH [1 ]
Gilula, LA [1 ]
Lashgari, CJ [1 ]
Riew, KD [1 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO 63110 USA
来源
JOURNAL OF SPINAL DISORDERS | 2000年 / 13卷 / 06期
关键词
titanium mesh cages; case complications; spinal fusion;
D O I
10.1097/00002517-200012000-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Carbon fiber and titanium cage implantation for anterior column support during spinal fusions is an alternative to the use of more traditional structural allografts and autografts. The authors report instrumentation and cage failure for patients who underwent spinal fusion with structural titanium mesh cages implanted into the anterior column a minimum of 2 years after surgery. They wanted to determine whether plain radiographic techniques can be used to critically assess disk space and corpectomy fusions after implantation of these radioopaque cages. Fifty patients having undergone spinal fusions using structural titanium mesh cages in the anterior column had 99 anterior levels fused with at least 1 (maximum of 2) titanium mesh cage, resulting in a total of 131 cages used. The cages were examined for evidence of settling, migration, or failure. The anterior and posterior instrumentation was assessed for evidence of failure, and the spine was examined for evidence of successful fusion. Radiographic cage settling (>2 mm) into the vertebral body end plates was observed, but cage migration or failure were not. An average lordotic correction of 10 degrees was observed, with loss of correction into kyphosis from immediately after operation to final follow-up averaging 2 degrees. As an average of all reviewers, using a strict radiographic fusion assessment, definite or probable anterior fusion was graded at 81% of the levels, probably not or no at 5% of the levels, and could not be assessed at 14% of the levels. Definite or probable posterior fusion as an average of all reviewers was graded at 44% of the posterior fusion levels, questionable at 4%, no at 5%, and could not be assessed at 47%. The use of anterior-only, posterior-only, or anterior and posterior instrumentation with structural titanium mesh cages in the anterior spine along with proper autogenous bone grafting techniques provided anterior column support with a low rate of radiographic complications. Acceptable anterior spinal fusion rates, as assessed by a consensus agreement of reviewers, were observed primarily by evaluation of the fusion mass around the cages (extracage fusion), because intracage fusion was difficult to assess.
引用
收藏
页码:501 / 509
页数:9
相关论文
共 9 条
[1]  
BATTERMAN GR, 1997, SPINE, V22, P2748
[2]   CAN LUMBAR SPINE RADIOGRAPHS ACCURATELY DETERMINE FUSION IN POSTOPERATIVE-PATIENTS - CORRELATION OF ROUTINE RADIOGRAPHS WITH A 2ND SURGICAL LOOK AT LUMBAR FUSIONS [J].
BLUMENTHAL, SL ;
GILL, K .
SPINE, 1993, 18 (09) :1186-1189
[3]   INTERBODY LUMBAR FUSION USING A CARBON-FIBER CAGE IMPLANT VERSUS ALLOGRAFT BONE - AN INVESTIGATIONAL STUDY IN THE SPANISH GOAT [J].
BRANTIGAN, JW ;
MCAFEE, PC ;
CUNNINGHAM, BW ;
WANG, H ;
ORBEGOSO, CM .
SPINE, 1994, 19 (13) :1436-1444
[4]   A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS [J].
BRANTIGAN, JW ;
STEFFEE, AD .
SPINE, 1993, 18 (14) :2106-2117
[5]  
BRIDWELL KH, 1995, SPINE, V20, P1410, DOI 10.1097/00007632-199506000-00014
[6]   CORRELATION OF RADIOLOGIC ASSESSMENT OF LUMBAR SPINE FUSIONS WITH SURGICAL EXPLORATION [J].
BRODSKY, AE ;
KOVALSKY, ES ;
KHALIL, MA .
SPINE, 1991, 16 (06) :S261-S265
[7]   Strength and stability of posterior lumbar interbody fusion - Comparison of titanium fiber mesh implant and tricortical bone graft [J].
Hoshijima, K ;
Nightingale, RW ;
Yu, JR ;
Richardson, WJ ;
Harper, KD ;
Yamamoto, H ;
Myers, BS .
SPINE, 1997, 22 (11) :1181-1188
[8]   ASSESSMENT OF BONY UNION AFTER INTERBODY FUSION OF THE LUMBAR SPINE USING A BIPLANAR RADIOGRAPHIC TECHNIQUE [J].
PEARCY, M ;
BURROUGH, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (02) :228-232
[9]   Threaded titanium cages for lumbar interbody fusions [J].
Ray, CD .
SPINE, 1997, 22 (06) :667-679