Intensity-modulated whole pelvic radiation therapy in patients with gynecologic malignancies

被引:332
作者
Roeske, JC
Lujan, A
Rotmensch, J
Waggoner, SE
Yamada, D
Mundt, AJ
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Obstet & Gynecol, Gynecol Oncol Sect, Chicago, IL 60637 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 05期
关键词
gynecology; whole pelvic radiation therapy; inverse planning; intensity modulation;
D O I
10.1016/S0360-3016(00)00771-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the ability of intensity-modulated radiation therapy (IMRT) to reduce the volume of small bowel irradiated in women with gynecologic malignancies receiving whole pelvic radiotherapy (WPRT). Methods and Materials: Ten women with cervical (5) or endometrial (5) cancer undergoing WPRT were selected for this analysis. A planning CT scan of each patient was obtained following administration of oral, i.v., and rectal contrast. The clinical target volume (CTV) was defined as the proximal vagina, parametrial tissues, uterus (if present), and regional lymph nodes. The CTV was expanded uniformly by 1 cm in all directions to produce a planning target volume (PTV). The bladder, rectum, and small bowel were also delineated in each patient. Two plans were created: a standard "4-field box" with apertures shaped to the PTV in each beam's eye view and an IM-WPRT plan designed to conform to the PTV while minimizing the volume of normal tissues irradiated. Both plans were normalized to deliver 45 Gy to the PTV. Isodose distributions and dose-volume histograms (DVH) were compared. Results: The IM-WPRT plan reduced the volume of small bowel irradiated in all 10 patients at doses above 30 Gy. At the prescription dose, the average volume of small bowel irradiated,vas reduced by a factor of two (17.4 vs. 33.8%,p = 0.0005). In addition, the average volume of rectum and bladder irradiated at the prescription dose was reduced by 23% in both cases (p = 0.0002 and p = 0.0005, respectively). The average PTV doses delivered by the conventional and IM-WPRT plans were 47.8 Gy and 47.4 Gy, respectively. Corresponding maximum doses were 50.0 Gy and 54.8 Gy, respectively. However, on average, only 3.2% of the PTV received greater than 50.0 Gy in the IM-WPRT plans. Conclusion: Our results suggest that IM-WPRT is an effective means of reducing the volume of small bowel irradiated in women with gynecologic malignancies receiving WPRT. This approach potentially offers a method for reducing small bowel complications in patients,vith gynecologic malignancies. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1613 / 1621
页数:9
相关论文
共 55 条
[1]   THE USE OF A PROSTHETIC TISSUE EXPANDER TO DISPLACE BOWEL FROM A BRACHYTHERAPY IMPLANT SITE [J].
ARMSTRONG, JG ;
HARRISON, LB ;
DATTOLI, M ;
CONCEPCION, R ;
MINSKY, BD ;
FORTNER, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (06) :1521-1523
[2]   CLINICAL AND NUTRITIONAL IMPLICATIONS OF RADIATION ENTERITIS [J].
BEER, WH ;
FAN, A ;
HALSTED, CH .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (01) :85-91
[3]  
Beyzadeoglu M, 1997, Radiat Med, V15, P1
[4]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[5]   Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer [J].
Buchali, A ;
Koswig, S ;
Dinges, S ;
Rosenthal, P ;
Salk, J ;
Lackner, G ;
Böhmer, D ;
Schlenger, L ;
Budach, V .
RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) :29-34
[6]   A COMPUTER-CONTROLLED RADIATION-THERAPY MACHINE FOR PELVIC AND PARA-AORTIC NODAL AREAS [J].
CHIN, LM ;
KIJEWSKI, PK ;
SVENSSON, GK ;
CHAFFEY, JT ;
LEVENE, MB ;
BJARNGARD, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (01) :61-70
[7]   IMPACT OF IMPROVED IRRADIATION TECHNIQUE, AGE, AND LYMPH-NODE SAMPLING ON THE SEVERE COMPLICATION RATE OF SURGICALLY STAGED ENDOMETRIAL CANCER-PATIENTS - A MULTIVARIATE-ANALYSIS [J].
CORN, BW ;
LANCIANO, RM ;
GREVEN, KM ;
NOUMOFF, J ;
SCHULTZ, D ;
HANKS, GE ;
FOWBLE, BL .
JOURNAL OF CLINICAL ONCOLOGY, 1994, 12 (03) :510-515
[8]  
COUCKE P A, 1992, Strahlentherapie und Onkologie, V168, P226
[9]   A quality control study of the accuracy of patient positioning in irradiation of pelvic fields [J].
Creutzberg, CL ;
Althof, VGM ;
deHoog, M ;
Visser, AG ;
Huizenga, H ;
Wijnmaalen, A ;
Levendag, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :697-708
[10]   Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields [J].
Das, IJ ;
Lanciano, RM ;
Movsas, B ;
Kagawa, K ;
Barnes, SJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :67-76