A quality control study of the accuracy of patient positioning in irradiation of pelvic fields

被引:65
作者
Creutzberg, CL [1 ]
Althof, VGM [1 ]
deHoog, M [1 ]
Visser, AG [1 ]
Huizenga, H [1 ]
Wijnmaalen, A [1 ]
Levendag, PC [1 ]
机构
[1] DR DANIEL DEN HOED CANC CTR,DEPT CLIN PHYS,3075 EA ROTTERDAM,NETHERLANDS
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 34卷 / 03期
关键词
quality assurance in radiotherapy; portal imaging; treatment verification; patient positioning; pelvic fields;
D O I
10.1016/0360-3016(95)02034-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Determining and improving the accuracy of patient positioning in pelvic fields. Methods and Materials: Small pelvic fields were studied in 16 patients treated for urological cancers using a three-field isocentric technique. Large pelvic fields were studied in 17 gynecological cancer patients treated with anterior and posterior (AP-PA) parallel opposed fields. Quantitative analysis of 645 megavolt images and comparison to 82 simulation images were carried out. Results: Small pelvic fields: for the position of the patient in the field, standard deviations of the difference between simulation (SIM) and treatment (MV) images were 3.4 mm in the lateral direction, 5.3 mm in the cranio-caudal direction, and 4.8 mm in the ventro-dorsal direction. Alterations in the positioning technique were made and tested. Large pelvic fields: differences between simulation and treatment images for the position of the patient in the field were 4 mm [1 standard deviation (SD)] in the lateral direction and 6.5 mm in the cranio-caudal direction. A systematic shift of the treatment field in the cranial direction had occurred in the majority of patients. A positioning technique using laser lines and marking of the caudal field border was shown to be more accurate. Conclusion: Studies of positioning accuracy in routine irradiation techniques are needed to obtain data for definition of the margins for each treatment site at each institution. Random variations should be kept at a minimum by monitoring and improving positioning techniques. Treatment verification by megavolt imaging or film should be used to detect and correct systematic variations early in the treatment series.
引用
收藏
页码:697 / 708
页数:12
相关论文
共 33 条
  • [1] ALTHOF VGM, 1990, 10TH P INT C US COMP, P107
  • [2] ALTHOF VGM, 1996, IN PRESS MED PHYS
  • [3] MEASUREMENT OF PROSTATE MOTION OVER THE COURSE OF RADIOTHERAPY
    BALTER, J
    SANDLER, HM
    LAM, K
    BREE, RL
    LICHTER, AS
    TENHAKEN, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 223 - 223
  • [4] ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS
    BALTER, JM
    CHEN, GTY
    PELIZZARI, CA
    KRISHNASAMY, S
    RUBIN, S
    VIJAYAKUMAR, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01): : 137 - 143
  • [5] ANALYSIS OF PROSTATE AND SEMINAL-VESICLE MOTION
    BEARD, CJ
    BUSSIERE, MR
    PLUNKETT, ME
    COLEMAN, CN
    KIJEWSKI, PK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 136 - 136
  • [6] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [7] MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER
    BIJHOLD, J
    LEBESQUE, JV
    HART, AAM
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) : 261 - 271
  • [8] WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS
    BYHARDT, RW
    COX, JD
    HORNBURG, A
    LIERMANN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10): : 881 - 887
  • [9] QUALITY ASSURANCE USING PORTAL IMAGING - THE ACCURACY OF PATIENT POSITIONING IN IRRADIATION OF BREAST-CANCER
    CREUTZBERG, CL
    ALTHOF, VGM
    HUIZENGA, H
    VISSER, AG
    LEVENDAG, PC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 529 - 539
  • [10] ACCURACY OF PATIENT POSITIONING IN MANTLE FIELD IRRADIATION
    CREUTZBERG, CL
    VISSER, AG
    DEPORRE, PMZR
    MEERWALDT, JH
    ALTHOF, VGM
    LEVENDAG, PC
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) : 257 - 264