Determination of trace elements in zeolites by laser ablation ICP-MS

被引:36
作者
Pickhardt, C
Brenner, IB
Becker, JS
Dietze, HJ
机构
[1] Forschungszentrum Julich, Zent Abt Chem Anal, D-52425 Julich, Germany
[2] Malkha BGU EAL, IL-96956 Jerusalem, Israel
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 368卷 / 01期
关键词
D O I
10.1007/s002160000514
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium berate mixture to increase the homogeneity and to eliminate mineralogical effects. Ln order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using: the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NLM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1-11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower mu g/g range (from 0.03 mu g/E for Lu, Ta and Th to 7.3 mu g/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (lambda: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 x 10(9) W/cm(2)) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 37 条
[1]   Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Bi, M ;
Aucelio, RQ ;
Smith, BW ;
Winefordner, JD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) :19-26
[2]   Mass spectrometric analysis of ceramic components for solid oxide fuel cells [J].
Becker, JS ;
Westheide, J ;
Saprykin, AI ;
Holzbrecher, H ;
Breuer, U ;
Dietze, HJ .
MIKROCHIMICA ACTA, 1997, 125 (1-4) :153-160
[3]   Inorganic mass spectrometric methods for trace, ultratrace, isotope, and surface analysis [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :1-35
[4]   LASER IONIZATION MASS-SPECTROMETRY IN INORGANIC TRACE ANALYSIS [J].
BECKER, JS ;
DIETZE, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (03) :69-86
[5]   Determination of trace elements in geological samples by laser ablation inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :429-434
[6]  
Brenner IB, 1996, FRESEN J ANAL CHEM, V355, P559
[7]  
CADENA F, 1994, RADIOACT WASTE MANAG, V18, P27
[8]   FRACTIONATION EFFECTS IN LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CROMWELL, EF ;
ARROWSMITH, P .
APPLIED SPECTROSCOPY, 1995, 49 (11) :1652-1660
[9]   THE SOLUBILITY AND OXIDATION-STATE OF NICKEL IN SILICATE MELT AT LOW-OXYGEN FUGACITIES - RESULTS USING A MECHANICALLY ASSISTED EQUILIBRATION TECHNIQUE [J].
DINGWELL, DB ;
ONEILL, HSC ;
ERTEL, W ;
SPETTEL, B .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1994, 58 (08) :1967-1974
[10]   Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects [J].
Durrant, SF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1385-1403