Mass spectrometric analysis of ceramic components for solid oxide fuel cells

被引:22
作者
Becker, JS
Westheide, J
Saprykin, AI
Holzbrecher, H
Breuer, U
Dietze, HJ
机构
[1] Research Centre Juelich,Central Department of Analytical Chemistry
关键词
mass spectrometry; solid oxide fuel cells; trace analysis;
D O I
10.1007/BF01246179
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the determination of trace impurities in ceramic components of solid oxide Fuel cells (SOFCs), some mass spectrometric methods have been applied such as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and inductively coupled plasma mass spectrometry (ICP-MS). Due to a lack of suitable standard reference materials for quantifying of analytical results on LaxSryMnO3 cathode material a matrix-matched synthetic standard - high purity initial compounds doped with trace elements - was prepared in order to determine the relative sensitivity coefficients in SSMS and LA-ICP-MS. Radiofrequency glow discharge mass spectrometry (rf-GDMS) was developed for trace analysis and depth profiling of thick non-conducting layers. Surface analytical techniques, such as secondary ion mass spectrometry (SIMS) and sputtered neutral mass spectrometry (SNMS), were used to determine the element distribution on surfaces (homogeneity) and the surface contaminants of SOFC ceramic layers.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 14 条
[1]  
Becker JS, 1996, FRESEN J ANAL CHEM, V355, P626
[2]   LASER IONIZATION MASS-SPECTROMETRY IN INORGANIC TRACE ANALYSIS [J].
BECKER, JS ;
DIETZE, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (03) :69-86
[3]  
BECKER JS, 1996, BERICHTE FORSCHUNGSZ, V3272, P36
[4]   ANALYSIS OF ADVANCED CERAMICS AND THEIR BASIC PRODUCTS [J].
BROEKAERT, JAC ;
GRAULE, T ;
JENETT, H ;
TOLG, G ;
TSCHOPEL, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 332 (08) :825-838
[5]  
DIETZE HJ, 1993, CHEM ANAL SERIES, V124, P453
[6]  
DIETZE HJ, 1991, ANALYTIKERTASCHENBUC, V10, P249
[7]  
HILPERT K, 1995, COMMUNICATION
[8]  
MALLENER W, 1992, P INT THERM SPAR C E, P835
[9]   RADIOFREQUENCY GLOW-DISCHARGE ION-SOURCE FOR HIGH-RESOLUTION MASS-SPECTROMETRY [J].
SAPRYKIN, AI ;
MELCHERS, FG ;
BECKER, JS ;
DIETZE, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 353 (5-8) :570-574
[10]   CHARACTERIZATION AND OPTIMIZATION OF A RADIOFREQUENCY GLOW-DISCHARGE ION-SOURCE FOR A HIGH-RESOLUTION MASS-SPECTROMETER [J].
SAPRYKIN, AI ;
BECKER, JS ;
DIETZE, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) :897-901