Gas phase detection of explosives such as 2,4,6-trinitrotoluene by molecularly imprinted polymers

被引:99
作者
Bunte, Gudrun [1 ]
Huerttlen, Juergen [1 ]
Pontius, Heike [1 ]
Hartlieb, Kerstin [1 ]
Krause, Horst [1 ]
机构
[1] Fraunhofer Inst Chem Technol, D-76327 Pfinztal, Germany
关键词
detection of explosive vapours; low-cost sensors; molecularly imprinted polymers (MIP); quartz crystal microbalance (QCM); suspension polymerisation; polymerisation initiated by ultraviolet light (UV);
D O I
10.1016/j.aca.2007.02.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast, reliable and inexpensive analytical techniques for trace detection of explosive components are in high demand. Our approach is to develop specific sensor coating materials based on molecularly imprinted polymers (MIPs). Despite the known inhibition of radical polymerisations by nitro groups and the known shrinkage of the polymer lattice during/after drying we were able to synthesize particulate MIPs by suspension polymerisation as well as thin MIP coatings by direct surface polymerisation on quartz crystal microbalances (QCM). The best method to purify the porous beads was Soxhlet extraction followed by supercritical carbon dioxide extraction (SFE with sc-CO2) at mild conditions (150 bar, 50 degrees C). At least a removal of >99.7% of the template was achieved. Performance tests of TNT imprinted polymer beads showed that acrylamide (AA) and more pronounced also methacrylic acid (MAA) possessed an enhanced adsorption tendency for gaseous TNT. An adsorption of 2,4-DNT, dinitrotoluene, by these MIPs was not detected. Using 2,4-DNT as template and methacrylamide, MAAM, a positive imprint effect for gaseous 2,4-DNT was achieved with no measurable cross-sensitivity for 2,4,6-TNT. The thin MIP coatings directly synthesized on the QCMs showed thicknesses of 20 to up to 500 nm. Preliminary screening experiments were performed for five different monomers and three different solvents (acetonitrile, chloroform and dimethylformamide). Best adsorption properties for TNT vapour until now showed a PAA-MIP synthesized with chloroform. Direct measurements of the mass attachment, respectively frequency decrease of the coated QCMs during vapour treatment showed a TNT-uptake of about 150 pg per jig MIP per hour. Results look worthy for further studies. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 28 条
[11]   Mass-sensitive detection of cells, viruses and enzymes with artificial receptors [J].
Hayden, O ;
Bindeus, R ;
Haderspöck, C ;
Mann, KJ ;
Wirl, B ;
Dickert, FL .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :316-319
[12]  
HURTTLEN J, 2005, P 7 DRESDN SENS S DE
[13]  
KOMIYAMA M, 2003, MOL IMPRINTING
[14]   Preparation and evaluation of molecularly imprinted polymeric microspheres by aqueous suspension polymerization for use as a high-performance liquid chromatography stationary phase [J].
Lai, JP ;
Lu, XY ;
Lu, CY ;
Ju, HF ;
He, XW .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :105-111
[15]   Bulk acoustic wave sensor for herbicide assay based on molecularly imprinted polymer [J].
Liang, CD ;
Peng, H ;
Nie, LH ;
Yao, SZ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (06) :551-555
[16]  
LUCKLUM R, THESIS U MAGDEBURG
[17]   Molecularly imprinted polymer beads: Suspension polymerization using a liquid perfluorocarbon as the dispersing phase [J].
Mayes, AG ;
Mosbach, K .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3769-3774
[18]  
Mosbach K, 1998, J MOL RECOGNIT, V11, P62, DOI 10.1002/(SICI)1099-1352(199812)11:1/6<62::AID-JMR391>3.0.CO
[19]  
2-5
[20]  
MURRAY GM, 1997, J HOPKINS APL TECH D, V18