Intercalibration of FTIR and SIMS for hydrogen measurements in glasses and nominally anhydrous minerals

被引:135
作者
Aubaud, Cyril
Withers, Anthony C.
Hirschmann, Marc M.
Guan, Yunbin
Leshin, Laurie A.
Mackwell, Stephen J.
Bell, David R.
机构
[1] Univ Minnesota, Dept Geol & Geophys, Minneapolis, MN 55455 USA
[2] Arizona State Univ, Dept Geol, Tempe, AZ 85287 USA
[3] Lunar & Planetary Inst, Houston, TX 77058 USA
[4] Arizona State Univ, Dept Chem & Biochem, Tempe, AZ 85282 USA
关键词
spectroscopy; infrared; water; mantle; ion microprobe;
D O I
10.2138/am.2007.2248
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We present new Fourier Transform Infrared Spectroscopy (FTIR) and ion microprobe/secondary ion mass spectrometry (SIMS) analyses of H-1 in 61 natural and experimental geological samples. These samples include 8 basaltic glasses (0.17 to 7.65 wt% H2O), 11 rhyolitic glasses (0.143 to 6.20 wt% H2O), 17 olivines (similar to 0 to 910 wt. ppin H2O), 9 orthopyroxenes (similar to 0 to 263 wt. ppin H2O), 8 clinopyroxenes (similar to 0 to 490 wt. ppin H2O), and 8 garnets (similar to 0 to 189 wt. ppm H2O). By careful attention to vacuum quality, the use a Cs+ primary beam, and a resin-free mounting technique, we routinely achieve hydrogen backgrounds equivalent to less than 5 ppm by weight H2O in olivine. Compared to previous efforts, the new calibration extends to a wider range of H2O contents for the minerals and is more reliable owing to a larger number of standards and to characterization of anisotropic minerals by polarized FTIR on oriented crystals. When observed, discrepancies between FTIR and SIMS measurements are attributable to inclusions of hydrous minerals or fluid inclusions in the crystals. Inclusions more commonly interfere with FTIR analyses than with SIMS, owing to the much larger volume sampled by the former. Plots of H2O determined by FTIR vs. (H-1/Si-30) x (SiO2), determined by SIMS and electron microprobe (EMP) yield linear arrays and for each phase appear to be insensitive to bulk composition. For example, basalt and rhyolite calibration slopes cannot be distinguished. On the other hand, calibration slopes of different phases vary by up to a factor of 4. This reflects either phase-specific behavior of H-1/Si-30 secondary ion ratios excited by Cs+ ion beams or discrepancies between phase-specific FTIR absorption coefficient schemes.
引用
收藏
页码:811 / 828
页数:18
相关论文
共 81 条
[31]   EXPERIMENTAL CONSTRAINTS ON THE DYNAMICS OF THE PARTIALLY MOLTEN UPPER-MANTLE .2. DEFORMATION IN THE DISLOCATION CREEP REGIME [J].
HIRTH, G ;
KOHLSTEDT, DL .
JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 1995, 100 (B8) :15441-15449
[32]   Water in the oceanic upper mantle: Implications for rheology, melt extraction and the evolution of the lithosphere [J].
Hirth, G ;
Kohlstedt, DL .
EARTH AND PLANETARY SCIENCE LETTERS, 1996, 144 (1-2) :93-108
[33]   Water content in the transition zone from electrical conductivity of wadsleyite and ringwoodite [J].
Huang, XG ;
Xu, YS ;
Karato, SI .
NATURE, 2005, 434 (7034) :746-749
[34]  
IHINGER PD, 1994, REV MINERAL, V30, P67
[35]  
INGRIN J, 1989, EUR J MINERAL, V1, P327
[36]  
Ishida K, 2001, AM MINERAL, V86, P965
[37]  
Jarosewich E.N., 1980, Geostandards Newsletter, V4, P43, DOI DOI 10.1111/J.1751-908X.1980.TB00273.X
[38]  
Jendrzejewski N, 1996, CR ACAD SCI II A, V322, P735
[39]   Water, partial melting and the origin of the seismic low velocity and high attenuation zone in the upper mantle [J].
Karato, S ;
Jung, H .
EARTH AND PLANETARY SCIENCE LETTERS, 1998, 157 (3-4) :193-207
[40]   THE ROLE OF HYDROGEN IN THE ELECTRICAL-CONDUCTIVITY OF THE UPPER MANTLE [J].
KARATO, S .
NATURE, 1990, 347 (6290) :272-273