Multiecho imaging with suboptimal spoiler gradients

被引:12
作者
Does, MD [1 ]
Snyder, RE [1 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 2G3, Canada
基金
英国医学研究理事会;
关键词
magnetic resonance imaging; transverse (T-2) relaxation; multiecho imaging; spoiler gradients;
D O I
10.1006/jmre.1997.1320
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Although multiecho imaging may be used to measure transverse relaxation (T-2), B-1 and B-0 inhomogeneity generally gives rise to unwanted coherence pathway signals which result in erroneous T-2 measurements. One approach to suppressing this unwanted signal is to center each rf refocusing pulse between spoiler gradients which dephase the unwanted signal; however, hardware limitations often dictate the use of suboptimal spoiler gradients, that is, gradients that cannot provide sufficient dephasing strength. Using simulations, this work demonstrates that by means of a small additional spoiler gradient prior to the first rf refocusing pulse it is possible to reduce substantially the contribution from unwanted coherence pathways in multiecho imaging studies that use suboptimal spoiler gradients. This reduction of unwanted signal results in measured T-2 values within approximate to 1% of values obtained using spoiler gradients of optimal strength. These results were found for a wide range of biologically relevant T-1 and T-2 values, missettings of the rf refocusing pulse as large as 5%, and frequency offsets of up to 25 Hz. Multiecho image data agreed with the simulations. Using the additional spoiler gradient it is possible to reduce spoiler gradient strengths by up to 75%. (C) 1998 academic Press.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 9 条
[1]
SUPPRESSION OF ARTIFACTS IN MULTIPLE-ECHO MAGNETIC-RESONANCE [J].
BARKER, GJ ;
MARECI, TH .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (01) :11-28
[2]
ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[3]
DIFFUSION AND FIELD-GRADIENT EFFECTS IN NMR FOURIER SPECTROSCOPY [J].
KAISER, R ;
BARTHOLDI, E ;
ERNST, RR .
JOURNAL OF CHEMICAL PHYSICS, 1974, 60 (08) :2966-2979
[4]
PRACTICAL T2 QUANTITATION FOR CLINICAL-APPLICATIONS [J].
POON, CS ;
HENKELMAN, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :541-553
[5]
180-DEGREES REFOCUSING PULSES WHICH ARE INSENSITIVE TO STATIC AND RADIOFREQUENCY FIELD INHOMOGENEITY [J].
POON, CS ;
HENKELMAN, RM .
JOURNAL OF MAGNETIC RESONANCE, 1992, 99 (01) :45-55
[6]
A SLICE-SELECTIVE ADIABATIC REFOCUSING PULSE MADE UP OF 2 ADIABATIC INVERSION PULSES - SUPPRESSION OF UNWANTED ECHOES [J].
SHEN, JF ;
SAUNDERS, JK .
JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (02) :381-386
[7]
GENERALIZATION OF THE PARTITION METHOD FOR CALCULATING ECHO MAGNITUDES [J].
SIMBRUNNER, J .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 109 (01) :117-120
[8]
[9]
MULTIECHO, SPIN-ECHO SEQUENCE TO ELIMINATE UNWANTED ECHOES [J].
ZUR, Y ;
ZOU, X ;
NEURINGER, LJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :464-469