Modified ultrafiltration improves left ventricular systolic function in infants after cardiopulmonary bypass

被引:90
作者
Davies, MJ
Nguyen, K
Gaynor, JW
Elliott, MJ
机构
[1] Great Ormond St Hosp Sick Children, Cardiothorac Unit, London WC1N 3JH, England
[2] Childrens Hosp Philadelphia, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S0022-5223(98)70280-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Our objective was to test the hypothesis that use of modified ultrafiltration after cardiopulmonary bypass improves intrinsic left ventricular systolic function in children. Methods: Twenty-one infants undergoing cardiopulmonary bypass were instrumented with ultrasonic dimension transducers, to measure the anteroposterior minor axis diameter, and a left ventricular micromanometer. Patients were randomized to modified ultrafiltration (n = 11, age 226 +/- 355 days, weight 6.7 +/- 3.1 kg) or control (n = 10, age 300 +/- 240 days, weight 7.0 +/- 2.5 kg) (all differences p > 0.05 between groups). Left ventricular systolic function was assessed by means of the slope of the preload-recruitable stroke work index. Myocardial cross-sectional area was measured by echocardiography. Data were acquired immediately after separation from bypass, at steady state, and during transient vena caval occlusion. Data acquisition was repeated after 13 +/- 5 minutes of modified ultrafiltration or after 12 +/- 5 minutes without modified ultrafiltration in the control group. Inotropic drug support was the same at both study points. Results: In the modified ultrafiltration group, the filtrate volume was 363 +/- 262 ml. The hematocrit value increased from 26.0% +/- 2.7% to 36.7% +/- 9.5% (p = 0.018), myocardial cross-sectional area decreased from 3.72 +/- 0.35 cm(2) to 3.63 +/- 0.36 cm(2) (p = 0.04), end-diastolic length increased from 25.6 +/- 9.0 mm to 28.8 +/- 9.9 mm (p = 0.01), and end-diastolic pressure fell from 5.6 +/- 0.8 mm Hg to 4.2 +/- 0.8 mm Hg (p = 0.005), suggesting an improved diastolic compliance. In the control group, the hematocrit value, myocardial cross-sectional area, end-diastolic length, and pressure did not change (all p > 0.05). Mean ejection pressure increased in the ultrafiltration group (p = 0.001) but did not change in the control group (p = 0.22). The slope of the preload-recruitable stroke work index increased after ultrafiltration from 52.3 +/- 52.0 to 74.2 +/- 66.0 (10(3) erg/cm(3)) (p = 0.02) but did not change in the control group (p = 0.07). One patient from each group died in the postoperative period. Patients in the ultrafiltration group received less inotropic drug support in the first 24 hours after the operation (156.62 +/- 92.31 mu g/kg in 24 hours) than patients in the control group (865.33 +/- 1772.26 mu g/kg in 24 hours, p = 0.03). Conclusions: Use of modified ultrafiltration after cardiopulmonary bypass improves intrinsic left ventricular systolic function, improves diastolic compliance, increases blood pressure, and decreases inotropic drug use in the early postoperative period.
引用
收藏
页码:361 / 369
页数:9
相关论文
共 25 条
[11]  
Hodges U M, 1994, J Cardiothorac Vasc Anesth, V8, P653, DOI 10.1016/1053-0770(94)90197-X
[12]   High-volume, zero-balanced hemofiltration to reduce delayed inflammatory response to cardiopulmonary bypass in children [J].
Joumois, D ;
IsraelBiet, D ;
Pouard, P ;
Rolland, B ;
Silvester, W ;
Vouhe, P ;
Safran, D .
ANESTHESIOLOGY, 1996, 85 (05) :965-976
[13]  
KIRKLIN J K, 1987, Blood Purification, V5, P168, DOI 10.1159/000169466
[14]  
KOPMAN EA, 1978, ANESTH ANALG, V57, P367
[15]  
LAKS H, 1977, J THORAC CARDIOV SUR, V73, P129
[16]   PERIOPERATIVE MONITORING OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE IN CHILDREN UNDERGOING OPEN-HEART-SURGERY [J].
MAEHARA, T ;
NOVAK, I ;
WYSE, RKH ;
ELLIOT, MJ .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (05) :258-265
[17]   CYTOKINE PRODUCTION AND HEMOFILTRATION IN CHILDREN UNDERGOING CARDIOPULMONARY BYPASS [J].
MILLAR, AB ;
ARMSTRONG, L ;
VANDERLINDEN, J ;
MOAT, N ;
EKROTH, R ;
WESTWICK, J ;
SCALLAN, M ;
LINCOLN, C .
ANNALS OF THORACIC SURGERY, 1993, 56 (06) :1499-1502
[18]   QUANTIFICATION OF THE CONTRACTILE RESPONSE TO INJURY - ASSESSMENT OF THE WORK-LENGTH RELATIONSHIP IN THE INTACT HEART [J].
MORRIS, JJ ;
PELLOM, GL ;
MURPHY, CE ;
SALTER, DR ;
GOLDSTEIN, JP ;
WECHSLER, AS .
CIRCULATION, 1987, 76 (03) :717-727
[19]  
NAIK S K, 1991, Perfusion (London), V6, P41, DOI 10.1177/026765919100600106
[20]  
NAIK SK, 1991, CIRCULATION, V84, P422