Anomalous hemodynamic effects of a self-expanding intracranial stent: Comparing in-vitro and ex-vivo models using ultra-high resolution MicroCT based CFD

被引:9
作者
Benndorf, Goetz [1 ]
Ionescu, Mircea [2 ]
Valdivia y Alvarado, Miguel [4 ]
Biondi, Alessandra [5 ]
Hipp, John [1 ]
Metcalfe, Ralph [2 ,3 ]
机构
[1] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[2] Univ Houston, Dept Mech Engn, Houston, TX USA
[3] Univ Houston, Biomed Engn Program, Houston, TX USA
[4] Methodist Hosp, Res Inst, Houston, TX 77030 USA
[5] Hop La Pitie Salpetriere, Dept Neuroradiol, Paris, France
关键词
Stent; MicroCT; CHD; CFD; Restenosis; WALL SHEAR-STRESS; COMPUTATIONAL FLUID-DYNAMICS; NEOINTIMAL HYPERPLASIA; CEREBRAL ANEURYSMS; BLOOD-FLOW; IMPLANTATION; RESTENOSIS; PLACEMENT; STENOSIS; SUBJECT;
D O I
10.1016/j.jbiomech.2009.10.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Previous research on the effects of intracranial stents on arterial hemodynamics has involved computational hemodynamics (CHD) simulations applied to artificially generated stent models. In this study, accurate geometric reconstructions of in-vitro (PTFE tube) and ex-vivo (canine artery) deployed stents based on ultra-high resolution MicroCT imaging were used. The primary goal was to compare the hemodynamic effects of deployment in these two different models and to identify flow perturbations due to deployment anomalies such as scent malapposition and strut prolapse, important adverse mechanics occurring in clinical practice, but not considered in studies using idealized stent models. Ultra-high resolution MicroCT data provided detailed visualization of deployment characteristics allowing for accurate in-stent flow simulation. For stent cells that are regularly and symmetrically deployed, the near wall flow velocities and wall shear stresses were similar to previously published results derived from idealized models. In-stent hemodynamics were significantly altered by misaligned or malapposed stent cells, important effects not realistically captured in previous models. This research shows the feasibility and value of an ex-vivo stent model for MicroCT based CHD studies. It validates previous in-vitro studies and further contributes to the understanding of in-stent hemodynamics associated with adverse mechanics of self-expanding intracranial stents. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:740 / 748
页数:9
相关论文
共 37 条
[1]   Effects of different stent designs on local hemodynamics in stented arteries [J].
Balossino, Rossella ;
Gervaso, Francesca ;
Migliavacca, Francesco ;
Dubini, Gabriele .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1053-1061
[2]  
Banerjee RK, 2007, BIORHEOLOGY, V44, P91
[3]   Wall Shear Stress in Intracranial Self-Expanding Stents Studied Using Ultra-High-Resolution 3D Reconstructions [J].
Benndorf, G. ;
Ionescu, M. ;
Alvarado, M. V. y ;
Hipp, J. ;
Metcalfe, R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (03) :479-486
[4]  
Benndorf G, 2006, NEUROSURGERY, V58, P380, DOI DOI 10.1227/01.NEU.0000205287.06739.E1
[5]   Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC .
JOURNAL OF NEUROSURGERY, 2005, 103 (01) :146-155
[6]   Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique [J].
Cebral, JR ;
Löhner, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :468-476
[7]   Systemic inflammation induced by lipopolysaccharide increases neointimal formation after balloon and stent injury in rabbits [J].
Danenberg, HD ;
Welt, FGP ;
Walker, M ;
Seifert, P ;
Toegel, GS ;
Edelman, ER .
CIRCULATION, 2002, 105 (24) :2917-2922
[8]  
Doerfler A, 2005, AM J NEURORADIOL, V26, P862
[9]  
EBRAHIMI N, 2007, ASNR
[10]   Usefulness of the neuroform stent for the treatment of cerebral aneurysms: Results at initial (3-6-mo) follow-up [J].
Fiorella, D ;
Albuquerque, FC ;
Deshmukh, VR ;
McDougall, CG .
NEUROSURGERY, 2005, 56 (06) :1191-1201