Small-bowel diseases: Prospective evaluation of multi-detector row helical CT enteroclysis in 107 consecutive patients

被引:149
作者
Boudiaf, M
Jaff, A
Soyer, P
Bouhnik, Y
Hamzi, L
Rymer, R
机构
[1] Hop Lariboisiere, Dept Body & Vasc Imaging, AP HP, F-75475 Paris 10, France
[2] Hop Lariboisiere, Dept Gastroenterol, AP HP, F-75475 Paris, France
关键词
computed tomography (CT); multi-detector row; enteroclysis; intestines; CT; diseases;
D O I
10.1148/radiol.2332030308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively evaluate multi-detector row helical computed tomographic (CT) enteroclysis for the depiction of small-bowel diseases. MATERIALS AND METHODS: The study group included 107 patients who were suspected of having small-bowel tumor (n = 8), active inflammatory small-bowel disease (n = 18), unexplained gastrointestinal bleeding (n = 36), refractory celiac sprue (n = 14), and low-grade small-bowel obstruction (n = 31). A nasoenteric tube was positioned into the duodenojejunal junction by using fluoroscopic guidance and water was infused with a pressure-controlled pump. After intravenous administration of 120 mL of iodinated contrast material, multi-detector row helical CT enteroclysis images were obtained with 4 x 2.5 mm collimation (four detector rows and 2.5-mm section thickness). Multi-detector row helical CT enteroclysis findings were analyzed by two readers working in consensus. Findings were compared with the results of endoscopy, enteroscopy, videocapsule endoscopy, histopathologic analysis, or clinical follow-up. RESULTS: Multi-detector row helical CT enteroclysis was well tolerated in 106 patients; one patient complained of abdominal pain after the examination. Multi-detector row helical CT enteroclysis allowed the diagnosis of small-bowel masses (n = 21), active Crohn disease (n = 9), small-bowel tuberculosis (n = 2), small-bowel lymphoma complicating celiac disease (n = 4), and confirmed low-grade small-bowel obstruction (n = 12). Multi-detector row helical CT enteroclysis demonstrated normal findings in 60 patients. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of multi-detector row helical CT enteroclysis were 100%, 95%, 97%, 94%, and 100%, respectively. CONCLUSION: Multi-detector row helical CT enteroclysis allows depiction of small-bowel diseases in patients suspected of having small-bowel conditions. (C) RSNA, 2004.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 10 条
  • [1] [Anonymous], EMERG RADIOL
  • [2] Arciero C A., 2001, Curr Surg, V58, P205, DOI 10.1016/S0149-7944(00)00454-2
  • [3] Computed tomographic enteroclysis - One methodology
    Bender, GN
    Timmons, JH
    Williard, WC
    Carter, J
    [J]. INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 43 - 49
  • [4] CT enteroclysis:: A superfluous diagnostic procedure or valuable when investigating small-bowel disease?
    Bender, GN
    Maglinte, DDT
    Klöppel, VR
    Timmons, JH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) : 373 - 378
  • [5] GAY G, 1992, ANN CHIR, V46, P417
  • [6] CT, SELLINK METHOD
    KLOPPEL, R
    THIELE, J
    BOSSE, J
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (03): : 291 - 292
  • [7] SMALL-BOWEL RADIOGRAPHY - HOW, WHEN, AND WHY
    MAGLINTE, DDT
    LAPPAS, JC
    KELVIN, FM
    REX, D
    CHERNISH, SM
    [J]. RADIOLOGY, 1987, 163 (02) : 297 - 305
  • [8] Orjollet-Lecoanet C, 2000, J RADIOL, V81, P618
  • [9] Findings at helical CT-enteroclysis in symptomatic patients with Crohn disease: Correlation with endoscopic and surgical findings
    Turetschek, K
    Schober, E
    Wunderbaldinger, P
    Bernhard, C
    Schima, W
    Puespoek, A
    Vogelsang, H
    Moeschl, P
    Mostbeck, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) : 488 - 492
  • [10] Diagnostic yield of wireless capsule enteroscopy in comparison with computed tomography enteroclysis
    Voderholzer, WA
    Ortner, M
    Rogalla, P
    Beinhölzl, J
    Lochs, H
    [J]. ENDOSCOPY, 2003, 35 (12) : 1009 - 1014