摘要
The enantiomeric separation of some nonsteroidal anti-inflammatory drugs (NSAIDs) was investigated in capillary electrophoresis (CE) using dual systems with mixtures of charged cyclodextrin (CD) derivatives. A significant enhancement of selectivity and resolution could be achieved in the enantioseparation of these analytes in their uncharged form by the simultaneous addition of two oppositely charged CD derivatives to the background electrolyte. The combination of the single-isomer cationic CD, permethyl-6-monoamino-6-monodeoxy-beta-CD (PMMAbetaCD) and the single-isomer polyanionic CD, heptakis-6-sulfato-beta-cyclodextrin (HSbetaCD) in a pH 2.5 phosphoric acid-triethanolamine buffer, was designed and employed for the enantioseparation of profens. The improvement in selectivity and resolution can be attributed to the fact that the two CDs, which lead to independent and enantioselective complexation with the analyte enantiomers, have not only opposite effects on the electrophoretic mobility of these compounds but also opposite affinity patterns towards the enantiomers of these compounds. Binding constants for these enantiomers with each CD were determined using linear regression approach, in order to be able to predict the effect of the concentrations of the two CDs on enantiomeric selectivity and resolution in such dual systems.
引用
收藏
页码:343 / 350
页数:8
相关论文
共 46 条
[1]  
Abushoffa AM, 2002, J SEP SCI, V25, P10, DOI 10.1002/1615-9314(20020101)25:1/2<10::AID-JSSC10>3.3.CO
[2]  
2-B
[3]   Prediction of selectivity for enantiomeric separations of uncharged compounds by capillary electrophoresis involving dual cyclodextrin systems [J].
Abushoffa, AM ;
Fillet, M ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :321-329
[4]  
Assi KA, 1999, ELECTROPHORESIS, V20, P2723, DOI 10.1002/(SICI)1522-2683(19990901)20:13<2723::AID-ELPS2723>3.0.CO
[5]  
2-O
[6]   Determination of trace enantiomeric impurities in chiral compounds by capillary electrophoresis with uncoated, cationic, anionic and neutral surface modified capillaries [J].
Assi, KH ;
Abushoffa, AM ;
Altria, KD ;
Clark, BJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :83-90
[7]   CHIRAL SEPARATION OF BASIC DRUGS BY CAPILLARY ZONE ELECTROPHORESIS WITH CYCLODEXTRIN ADDITIVES [J].
BECHET, I ;
PAQUES, P ;
FILLET, M ;
HUBERT, P ;
CROMMEN, J .
ELECTROPHORESIS, 1994, 15 (06) :818-823
[8]   Separation of profen enantiomers by capillary electrophoresis using cyclodextrins as chiral selectors [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pérez-Maseda, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (01) :165-175
[9]   Recent trends in enantioseparations using capillary electromigration techniques [J].
Chankvetadze, B .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (07) :485-498
[10]   Separation selectivity in chiral capillary electrophoresis with charged selectors [J].
Chankvetadze, B .
JOURNAL OF CHROMATOGRAPHY A, 1997, 792 (1-2) :269-295