The study was a clinical series of 95 ambulatory women with urinary incontinence. After voiding, each subject was scanned with a BladderScan BVI 2500, then catheterized for postvoid residual (PVR) and then scanned again. The mean PVR obtained by ultrasound was 49 mi. significantly larger than the mean PVR of 32 mi obtained by catheterization. Correlation analysis showed that the difference was not related to age. weight, body mass index, parity, pelvic prolapse or prior incontinence surgery, but was associated with prior hysterectomy and uterine prolapse. Regression analysis revealed that the difference was independently related to prior hysterectomy only. Postcatheterization ultrasound detected a mean of 22 mi. suggesting that the difference between the PVR values may be due to residual urine not removed by catheterization. Finally, ultrasound had a sensitivity; of 66.7% and a specificity of 96.5% in detecting PVR greater than or equal to 100 mi. Portable ultrasound scanners are quick, easy to use, reasonably sensitive, and very specific for determining elevated PVR.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 29 条
[1]  
*AHCPR, 1996, AHCPR PUBL
[2]   Bacterial vaginosis increases in pessary users [J].
Alnaif, B ;
Drutz, HP .
INTERNATIONAL UROGYNECOLOGY JOURNAL AND PELVIC FLOOR DYSFUNCTION, 2000, 11 (04) :219-223
[3]   Estimation of bladder volume using portable ultrasound in clam enterocystoplasty patients [J].
Barrington, JW ;
Jones, A ;
Robinson, J ;
Stephenson, TP .
JOURNAL OF UROLOGY, 1996, 155 (01) :82-83
[4]   ULTRASOUND ASSESSMENT OF RESIDUAL URINE - A QUANTITATIVE METHOD [J].
BEACOCK, CJM ;
ROBERTS, EE ;
REES, RWM ;
BUCK, AC .
BRITISH JOURNAL OF UROLOGY, 1985, 57 (04) :410-413
[5]   Portable ultrasound determination of urinary residual volume [J].
Bent A.E. ;
Nahhas D.E. ;
McLennan M.T. .
International Urogynecology Journal, 1997, 8 (4) :200-202
[6]   ACCURACY OF ULTRASONIC BLADDER VOLUME MEASUREMENT IN CHILDREN [J].
BIS, KG ;
SLOVIS, TL .
PEDIATRIC RADIOLOGY, 1990, 20 (06) :457-460
[7]  
CARDENAS DD, 1988, ARCH PHYS MED REHAB, V69, P514
[8]  
Chan H, 1993, J Neurosci Nurs, V25, P309
[9]   THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME [J].
COOMBES, GM ;
MILLARD, RJ .
JOURNAL OF UROLOGY, 1994, 152 (06) :2083-2085
[10]  
Corby V A, 1980, Radiography, V46, P187