Assessment of derived 12-lead electrocardiograms using general and patient-specific reconstruction strategies at rest and during transient myocardial ischemia

被引:10
作者
Nelwan, SP
Crater, SW
Green, CL
Johanson, P
van Dam, TB
Meij, SH
Simoons, ML
Krucoff, MW
机构
[1] Erasmus MC, Thoraxctr, NL-3000 GA Rotterdam, Netherlands
[2] Duke Univ, Med Ctr, Durham, NC USA
关键词
D O I
10.1016/j.amjcard.2004.08.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Twelve-lead ST-segment monitoring is a widely used tool for capturing focal ischemia and transient intermittent episodes. However, continuous registration of all 10 electrodes is impractical in clinical settings. This study investigated the accuracy of 2 derived 12-lead strategies that required 6 electrodes, including all limb leads, and 2 precordial leads by using population-based (generalized) and individualized (patient-specific) reconstruction coefficients to derive the additional 4 chest leads. A total of 26,880 simultaneous digital conventional 12-lead generalized and patient-specific electrocardiograms were monitored over 112 hours in 39 patients during percutaneous coronary intervention, including 159 balloon occlusions in 63 arteries, to test accuracy at rest and during ischemia. Occlusion duration was 78 seconds (range 42 to 96) in the left main coronary in 2 patients, the left anterior descending artery in 15, the right coronary artery in 10, the circumflex artery in 2, and graft segments in 5 patients. Average summated line was 377 muV (range 104 to 1,718), which increased at peak ischemia to an average of 1,086 muV (range 282 to 4,099). Median absolute differences at peak ischemic ST deviation were 25 muV in lead V-1, 0 muV in lead V-2, 35 muV in lead V-3, 34 muV in lead V-4, 0 muV in lead V-5, 11 muV in lead V-6, and 114 muV for summated 12-lead ST deviation with the generalized method and 7 muV in lead V-1, 4 muV in lead V-2, 1 muV in lead V-3, 5muV in lead V-4, 4 muV in lead V-5, 9 muV in lead V-6, and 83 muV for the summated 12-lead ST deviation with the patient-specific method. Limb leads (I, II, III, aVR, aVL, and aVF) were identical in all patients. Thus, generalized and patient-specific methods derived from 12-lead electrocardiography using actual limb and 2 precordial electrodes accurately derived the additional chest leads at rest and during ischemia. These approaches appear to be more practical than conventional 10-electrode monitoring but preserve high accuracy. (C) 2004 by Excerpta Medica Inc.
引用
收藏
页码:1529 / 1533
页数:5
相关论文
共 9 条
[1]  
Drew B J, 1999, Am J Crit Care, V8, P372
[2]  
Drew B J, 1996, Am J Crit Care, V5, P198
[3]   Comparison of standard and derived 12-lead electrocardiograms for diagnosis of coronary angioplasty-induced myocardial ischemia [J].
Drew, BJ ;
Adams, MG ;
Pelter, MM ;
Wung, SF ;
Caldwell, MA .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (05) :639-644
[4]   Continuous ST monitoring:: A bedside instrument?: A report from the Assessment of the Safety of a New Thrombolytic (ASSENT 2) ST monitoring substudy [J].
Johanson, P ;
Rössberg, J ;
Dellborg, M .
AMERICAN HEART JOURNAL, 2001, 142 (01) :58-62
[5]   Reduction of recurrent ischemia with abciximab during continuous ECG-ischemia monitoring in patients with unstable angina refractory to standard treatment (CAPTURE) [J].
Klootwijk, P ;
Meij, S ;
Melkert, R ;
Lenderink, T ;
Simoons, ML .
CIRCULATION, 1998, 98 (14) :1358-1364
[6]  
KRUCOFF MW, 1993, J ELECTROCARDIOL, V26, P249
[7]   STABILITY OF MULTILEAD ST-SEGMENT FINGERPRINTS OVER TIME AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY AND ITS USEFULNESS IN DETECTING REOCCLUSION [J].
KRUCOFF, MW ;
PARENTE, AR ;
BOTTNER, RK ;
RENZI, RH ;
STARK, KS ;
SHUGOLL, RA ;
AHMED, SW ;
DEMICHELE, J ;
STROMING, SL ;
GREEN, CE ;
RACKLEY, CE ;
KENT, KM .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1232-1237
[8]   A NEW SYSTEM OF MULTIPLE-LEAD EXERCISE ELECTROCARDIOGRAPHY [J].
MASON, RE ;
LIKAR, I .
AMERICAN HEART JOURNAL, 1966, 71 (02) :196-&
[9]   Minimal lead sets for reconstruction of 12-lead electrocardiograms [J].
Nelwan, SP ;
Kors, JA ;
Meij, SH .
JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 :163-166