Study of mixed Langmuir-Blodgett films of immunoglobulin G/amphiphile and their application for immunosensor engineering

被引:21
作者
Hou, YX
Tlili, C
Jaffrezic-Renault, N
Zhang, AD
Martelet, C
Ponsonnet, L
Errachid, A
Samitier, J
Bausells, J
机构
[1] Ecole Cent Lyon, IFOS, CNRS, UMR 5621, F-69131 Ecully, France
[2] Cent China Normal Univ, Coll Chem, Wuhan 430079, Peoples R China
[3] FSc Monastir, LPCI, Monastir 5000, Tunisia
[4] Lab Nanobioengn, Barcelona 08028, Spain
[5] Ctr Nacl Microelect IMB CSIC, Barcelona 08193, Spain
关键词
LB films; immunoglobulin G; octadecylamine; behenic acid; ac impedance; immunosensors;
D O I
10.1016/j.bios.2004.05.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Langmuir-Blodgett (LB) technique appears to be quite suitable for generating biospecific surfaces and it has potential application for fabricating biosensors. In this work, mixed Langmuir-Blodgett films of immunoglobulin G/amphiphile have been transferred onto hydrophobic silver surface previously modified by I-octadecanethiol (ODT) SAMs. In order to obtain stable LB films, the influences of different parameters - type of amphiphile, surface pressure and pH - on the properties of mixed IgG/amphiphile monolayer. were investigated. Electrochemical properties of the engineered immunosensor have been measured by impedimetric spectroscopy. The immunosensor obtained exhibits a high sensitivity and a good specificity in a linear dynamic range from 200 to 1000 ng ml(-1). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1126 / 1133
页数:8
相关论文
共 26 条
[1]   STUDY OF IMMUNOGLOBULIN-G THIN-LAYERS OBTAINED BY THE LANGMUIR-BLODGETT METHOD - APPLICATION TO IMMUNOSENSORS [J].
BARRAUD, A ;
PERROT, H ;
BILLARD, V ;
MARTELET, C ;
THERASSE, J .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (01) :39-48
[2]  
BERTOLD H, 1997, ANAL CHIM ACTA, V347, P177
[3]  
Chovelon J.-M., 2001, Journal of Biological Physics and Chemistry, V1, P68, DOI 10.4024/08CH01A.01.02
[4]   Influence of the surface pressure on the organization of mixed Langmuir-Blodgett films of octadecylamine and butyrylcholinesterase. 2. Film transferred onto silica support [J].
Chovelon, JM ;
Gaillard, F ;
Wan, K ;
Jaffrezic-Renault, N .
LANGMUIR, 2000, 16 (15) :6228-6232
[5]   The study of the antigen-antibody reaction by fluorescence method in LB films for immunosensor [J].
Chudinova, GK ;
Chudinov, AV ;
Savransky, VV ;
Prokhorov, AM .
THIN SOLID FILMS, 1997, 307 (1-2) :294-297
[6]   IMPEDANCE BASED SENSING OF THE SPECIFIC BINDING REACTION BETWEEN STAPHYLOCOCCUS ENTEROTOXIN-B AND ITS ANTIBODY ON AN ULTRA-THIN PLATINUM FILM [J].
DESILVA, MS ;
ZHANG, Y ;
HESKETH, PJ ;
MACLAY, GJ ;
GENDEL, SM ;
STETTER, JR .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) :675-682
[7]   DETERMINATION OF ORIENTATION OF THE IGG MOLECULES IN IMMOBILIZED LANGMUIR MONOLAYERS BY MEANS OF BINDING WITH FRAGMENT SPECIFIC ANTIIMMUNOGLOBULIN ANTIBODIES [J].
DUBROVSKY, T ;
TRONIN, A ;
NICOLINI, C .
THIN SOLID FILMS, 1995, 257 (01) :130-133
[8]   STRUCTURE OF CH3(CH2)17SH SELF-ASSEMBLED ON THE AG(111) SURFACE - AN INCOMMENSURATE MONOLAYER [J].
FENTER, P ;
EISENBERGER, P ;
LI, J ;
CAMILLONE, N ;
BERNASEK, S ;
SCOLES, G ;
RAMANARAYANAN, TA ;
LIANG, KS .
LANGMUIR, 1991, 7 (10) :2013-2016
[9]  
Foil C., 1995, THIN SOLID FILMS, V261, P287
[10]   LANGMUIR-BLODGETT FILMS OF LONG-CHAIN AMINES [J].
GAINES, GL .
NATURE, 1982, 298 (5874) :544-545