Multianalyte detection using a capillary-based flow immunosensor

被引:70
作者
Narang, U
Gauger, PR
Kusterbeck, AW
Ligler, FS
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] Georgetown Univ, Dept Biochem, Washington, DC 20007 USA
[3] Geocenters Inc, Ft Washington, MD 20744 USA
关键词
D O I
10.1006/abio.1997.2411
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive, dual-analyte detection system using capillary-based immunosensors has been designed for explosive detection. This model system consists of two capillaries, one coated with antibodies specific for 2,4,6-trinitrotoluene (TNT) and the other specific for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) combined into a single device. The fused silica capillaries are prepared by coating anti-TNT and anti-RDX antibodies onto the silanized inner walls using a heterobifunctional crosslinker. After immobilization, the antibodies are saturated with a suitable fluorophore-labeled antigen. A "T" connector is used to continuously flow the buffer solution through the individual capillaries. To perform the assay, an aliquot of TNT or RDX or a mixture of the two analytes is injected into the continuous flow stream. In each capillary, the target analyte displaces the fluorophore-labeled antigen from the binding pocket of the antibody. The labeled antigen displaced from either capillary is detected downstream using two portable spectrofluorometers. The limits of detection for TNT and RDX in the multianalyte format are 44 fmol (100 mu l of 0.1 ng/ml TNT solution) and 224 fmol (100 mu l of 0.5 ng/ml RDX solution), respectively. The entire assay for both analytes can be performed in less than 3 min. (C) 1998 Academic Press.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 28 条
  • [1] Bart JC, 1997, ACS SYM SER, V657, P210
  • [2] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [3] BLAKE C, 1982, CLIN CHEM, V28, P1469
  • [4] MULTIANALYTE IMMUNOASSAYS APPLICATION TO ENVIRONMENTAL-ANALYSIS
    BRECHT, A
    ABUKNESHA, R
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) : 361 - 371
  • [5] BROWN CR, 1985, CLIN CHEM, V31, P1500
  • [6] Simultaneous immunoassay using piezoelectric immunosensor array and robust method
    Chu, X
    Jiang, JH
    Shen, GL
    Yu, RQ
    [J]. ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 185 - 193
  • [7] DEMARS DD, 1989, CLIN CHEM, V35, P766
  • [8] DEVELOPING MULTIANALYTE ASSAYS
    EKINS, RP
    CHU, F
    [J]. TRENDS IN BIOTECHNOLOGY, 1994, 12 (03) : 89 - 94
  • [9] EKINS RP, 1995, ACS SYM SER, V586, P153
  • [10] MULTI-ANALYTE IMMUNOASSAY
    EKINS, RP
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (02) : 155 - 168