Optimization of conformal electron beam therapy using energy- and fluence-modulated beams

被引:43
作者
Hyodynmaa, S [1 ]
Gustafsson, A [1 ]
Brahme, A [1 ]
机构
[1] UNIV STOCKHOLM,S-17176 STOCKHOLM,SWEDEN
关键词
D O I
10.1118/1.597710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fluence modulation of multiple electron beams of various energies has been used to optimize the delivered dose distribution during electron beam radiation therapy. By maximizing the probability of achieving tumor control without causing severe complications electron beam fluence profiles have been optimized for superficial target volumes. It is possible to use several equiportal fluence-modulated electron beams to modify the energy deposition with depth in a controlled manner making it possible to use the technique as an alternative to bolus. The technique was tested in two representative phantom geometries and in three clinical patient geometries using a set of five and two different energies. The local maxima in dose for the plans with five energies were typically lower than with the conventional or advanced bolus techniques. The principles for how the technique could be carried out in the future with a fourth generation radiotherapy accelerator are also indicated. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:659 / 666
页数:8
相关论文
共 26 条
[11]   THE PROBLEM OF OBLIQUELY INCIDENT BEAMS IN ELECTRON-BEAM TREATMENT PLANNING [J].
EKSTRAND, KE ;
DIXON, RL .
MEDICAL PHYSICS, 1982, 9 (02) :276-278
[12]   PARTIAL BOLUSSING TO IMPROVE THE DEPTH DOSES IN THE SURFACE REGION OF LOW-ENERGY ELECTRON-BEAMS [J].
GALBRAITH, DM ;
RAWLINSON, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (02) :313-317
[13]   SIMULTANEOUS-OPTIMIZATION OF DYNAMIC MULTILEAF COLLIMATION AND SCANNING PATTERNS OR COMPENSATION FILTERS USING A GENERALIZED PENCIL BEAM ALGORITHM [J].
GUSTAFSSON, A ;
LIND, BK ;
SVENSSON, R ;
BRAHME, A .
MEDICAL PHYSICS, 1995, 22 (07) :1141-1156
[14]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[15]   WATER BAG BOLUS IN EXTERNAL AIR CAVITIES TO PRODUCE DOSE HOMOGENEITY [J].
HASELOW, RE ;
KHAN, FM ;
SHARMA, SC ;
WILLIAMSON, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (01) :137-139
[16]  
HOGSTROM KR, 1991, FRONTIERS RAD THERAP, P30
[17]   AN ALGORITHM FOR MAXIMIZING THE PROBABILITY OF COMPLICATION-FREE TUMOR-CONTROL IN RADIATION-THERAPY [J].
KALLMAN, P ;
LIND, BK ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :871-890
[18]   TUMOR AND NORMAL TISSUE RESPONSES TO FRACTIONATED NONUNIFORM DOSE DELIVERY [J].
KALLMAN, P ;
AGREN, A ;
BRAHME, A .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 62 (02) :249-262
[19]   ELECTRON-BEAM CHARACTERISTICS OF THE 50-MEV RACETRACK MICROTRON [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1992, 19 (02) :307-315
[20]   MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR [J].
KARLSSON, M ;
ZACKRISSON, B .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :317-326