Effective doses and organ doses per unit fluence calculated for monoenergetic 0.1 Mev to 100 MeV electrons by the MIRD-5 phantom

被引:17
作者
Katagiri, M [1 ]
Hikoji, M [1 ]
Kitaichi, M [1 ]
Sawamura, S [1 ]
Aoki, Y [1 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Kita Ku, Sapporo, Hokkaido 0608628, Japan
关键词
D O I
10.1093/oxfordjournals.rpd.a033165
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To determine quantities for radiation protection against high energy electrons, such as those from LINAC, the organ doses and effective doses were calculated using EGS-4 Monte Carlo simulation code and a MIRD-5 mathematical human phantom. Conversion coefficients for the incident fluence to the organ dose equivalent, to the effective dose, and to the effective dose equivalent for monoenergetic electrons were obtained for AP and PA irradiation geometries at incident energies from 0.1 to 100 MeV. The agreement between the results of the present study of effective doses and those of other studies is acceptable within the statistical uncertainties. At energies lower than 10 MeV, the skin sensitive layer was taken into account.
引用
收藏
页码:393 / 401
页数:9
相关论文
共 24 条
[21]   Organ and effective doses in the male phantom ADAM exposed in AP direction to broad unidirectional beams of monoenergetic electrons [J].
Schultz, FW ;
Zoetelief, J .
HEALTH PHYSICS, 1996, 70 (04) :498-504
[22]   Effective dose per unit fluence calculated for adults and a 7 year old girl in broad antero-posterior beams of monoenergetic electrons of 0.1 to 10 MeV [J].
Schultz, FW ;
Zoetelief, J .
RADIATION PROTECTION DOSIMETRY, 1997, 69 (03) :179-186
[23]  
SNYDER WS, 1978, 5 MIRD SOC NUCL MED
[24]  
TIPTON L, 1996, ORNL4007 HLTH PHYS D, P241