On-line preconcentration of weak electrolytes by electrokinetic accumulation in CE:: Experiment and simulation

被引:33
作者
Horakova, Jana
Petr, Jan
Maier, Vitezslav
Tesarova, Eva
Veis, Libor
Armstrong, Daniel W.
Gas, Bohuslav
Sevcik, Juraj
机构
[1] Palacky Univ, Dept Analyt Chem, CZ-77146 Olomouc, Czech Republic
[2] U Kabelovny, Prague, Czech Republic
[3] Charles Univ Prague, Fac Sci, Dept Phys & Macromol Chem, Prague, Czech Republic
[4] Univ Texas, Dept Chem & Biochem, Arlington, TX 76019 USA
关键词
CE; dynamic pH junction; electrokinetic accumulation; on-line preconcentration; simulation;
D O I
10.1002/elps.200600681
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry - benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.
引用
收藏
页码:1540 / 1547
页数:8
相关论文
共 42 条
[31]   Sweeping of analyte zones in electrokinetic chromatography [J].
Quirino, JP ;
Terabe, S .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1638-1644
[32]   Exceeding 5000-fold concentration of dilute analytes in micellar electrokinetic chromatography [J].
Quirino, JP ;
Terabe, S .
SCIENCE, 1998, 282 (5388) :465-468
[33]   COMPUTER-SIMULATION AND EXPERIMENTAL EVALUATION OF ON-COLUMN SAMPLE PRECONCENTRATION IN CAPILLARY ZONE ELECTROPHORESIS BY DISCONTINUOUS BUFFER SYSTEMS [J].
SCHWER, C ;
GAS, B ;
LOTTSPEICH, F ;
KENNDLER, E .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2108-2115
[34]  
Sentellas S, 2002, J SEP SCI, V25, P975, DOI 10.1002/1615-9314(20021101)25:15/17<975::AID-JSSC975>3.0.CO
[35]  
2-Y
[36]  
Shihabi ZK, 2002, ELECTROPHORESIS, V23, P1612, DOI 10.1002/1522-2683(200206)23:11<1612::AID-ELPS1612>3.0.CO
[37]  
2-3
[38]   Eigenmobilities in background electrolytes for capillary zone electrophoresis: III Linear theory of electromigration [J].
Stedry, M ;
Jaros, M ;
Hruska, V ;
Gas, B .
ELECTROPHORESIS, 2004, 25 (18-19) :3071-3079
[39]   ISOTACHOPHORESIS AS AN ONLINE CONCENTRATION PRETREATMENT TECHNIQUE IN CAPILLARY ELECTROPHORESIS [J].
STEGEHUIS, DS ;
IRTH, H ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1991, 538 (02) :393-402
[40]   Sensitivity improvement on detection of Coptidis alkaloids by sweeping in capillary electrophoresis [J].
Sun, SW ;
Tseng, HM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) :39-45