Is the atrial high rate episode diagnostic feature reliable in detecting paroxysmal episodes of atrial tachyarrhythmias?

被引:62
作者
Seidl, K
Meisel, E
VanAgt, E
Ottenhoff, F
Hess, M
Hauer, B
Zahn, R
Senges, J
机构
[1] Herzzentrum Ludwigshafen, Div Cardiol, Electrophysiol & Pacemaker Unit, D-67063 Ludwigshafen, Germany
[2] Univ Dresden, Med Ctr, Dresden, Germany
[3] Middelheim Hosp, B-2020 Antwerp, Belgium
[4] Bakken Res Ctr, Maastricht, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 04期
关键词
dual chamber pacemaker; diagnostic feature; atrial tachyarrhythmia;
D O I
10.1111/j.1540-8159.1998.tb00125.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The atrial high rate episode diagnostic in the Thera(R) pacemaker reports frequency, duration, and date/time of atrial tachyarrhythmias according to programmed criteria. The aim of the study tt as to validate the atrial high rate episode diagnostic feature. Episodes of atrial fibrillation recorded by Holter monitoring were compared to episodes detected bq the pacemaker. Forty five ambulatory (Holter) recordings were used for evaluation. Thirty of 45 ambulatory (Holter) recordings short ed sinus rhythm. On 4 of these 30 ambulatory (Holter) recordings, the Thera(R) detected 12 episodes of atrial tachyarrhythmias as false-positives (sinus rhythm was detected as atrial tachyarrhythmia). The main reason was far-field R and T wave oversensing. On 15 of 45 ambulatory (Holter) recordings, 125 episodes of atrial tachyarrhythmias were recorded. Ninety-three of these events also were detected by the pacemaker, while for 32 events the Thera(R) reported sinus rhythm. The main reason was that the episodes rr ere of too short duration. Therefore, the Thera(R) (programmed with detection rate 160 beats/min, detection beats 40, termination beats 10) was unable to detect atrial tachycardias. Software simulation of the diagnostic algorithm under several programming settings using the digitized Holter files demonstrated highly reliable detection of atrial tachyarrhythmias (sensitivity 98%, specificity 100%) when programmed as follows: defection rate 220 beats/min, detection beats 10, termination beats 20. It can be concluded that Thera(R)'s high rate episode monitor is a reliable tool for defection of atrial tachyarrhythmias, if programmed as recommended.
引用
收藏
页码:694 / 700
页数:7
相关论文
共 8 条
  • [1] DENDULK K, 1994, PACE, V17, P1900
  • [2] TRACKING OF ATRIAL-FLUTTER DURING DDD PACING - ANOTHER FORM OF PACEMAKER-MEDIATED TACHYCARDIA
    GREENSPON, AJ
    GREENBERG, RM
    FRANKL, WS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06): : 955 - 960
  • [3] CIRCUMVENTION OF MAXIMUM TRACKING LIMITATIONS WITH A RATE MODULATED DUAL CHAMBER PACEMAKER
    HANICH, RF
    MIDEI, MG
    MCELROY, BP
    BRINKER, JA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (02): : 392 - 397
  • [4] ATRIAL ARRHYTHMIA MANAGEMENT WITH SENSOR CONTROLLED ATRIAL REFRACTORY PERIOD AND AUTOMATIC-MODE SWITCHING IN PATIENTS WITH MINUTE VENTILATION SENSING DUAL CHAMBER RATE ADAPTIVE PACEMAKERS
    LAU, CP
    TAI, YT
    FONG, PC
    LI, JPS
    CHUNG, FLW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10): : 1504 - 1514
  • [5] A NEW FEATURE FOR CONTROL OF INAPPROPRIATE HIGH-RATE TRACKING IN DDDR PACEMAKERS
    LEE, MT
    ADKINS, A
    WOODSON, D
    VANDEGRIFF, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1852 - 1855
  • [6] LEVINE PA, 1983, CLIN PROG PACING ELE, V1, P275
  • [7] DUAL-CHAMBER, RATE-ADAPTIVE PACING IN PATIENTS WITH PAROXYSMAL SUPRAVENTRICULAR TACHYARRHYTHMIAS - PROTECTIVE MEASURES FOR RATE CONTROL
    MOND, HG
    BAROLD, SS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (11): : 2168 - 2185
  • [8] UNDESIRABLE MODE SWITCHING WITH A DUAL CHAMBER RATE RESPONSIVE PACEMAKER
    PITNEY, MR
    MAY, CD
    DAVIS, MJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (04): : 729 - 737