Nonlinear averaging reconstruction method for phase-cycle SSFP

被引:41
作者
Elliott, Andrew M. [1 ]
Bernstein, Matt A.
Ward, Heidi A.
Lane, John
Witte, Robert J.
机构
[1] MD Anderson Canc Ctr, Houston, TX 77030 USA
[2] Mayo Clin, Coll Med, Rochester, MN 55905 USA
关键词
phase cycle; SSFP; banding artifact; postprocessing; artifact reduction; cochlear nerves;
D O I
10.1016/j.mri.2006.09.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability to obtain high-quality images of small structures, such as the nerves of the inner ear, is important for the early diagnosis of numerous conditions. Balanced steady-state free precession (SSFP; e.g., true fast imaging with steady-state precession) is a fast acquisition method, but its use has been limited by the presence of off-resonance banding artifacts. To reduce these artifacts multiacquisition balanced SSFP with phase cycling is used, yielding multiple data sets in which the banding artifacts are spatially shifted with respect to each other (e.g., as in CISS). We present a new method, called nonlinear averaging (NLA), for combining these data sets to reduce banding artifacts. The NLA method arithmetically averages the three highest magnitude signals from four-phase-cycle SUP data on a pixel-by-pixel basis. Simulations indicate that NLA offers improved signal-to-noise ratio (SNR) over the more standard maximum intensity projection (MIP) reconstruction. NLA is compared to MIP in simulations and volunteer tests. Simulations suggest that NLA provides substantially improved SNR compared to MIP. In a randomized blinded comparison of 10 volunteer studies, two radiologists found that NLA, compared to MIP, gave improved results. NLA also provided superior noise reduction and enhanced edge sharpness compared to MIR We demonstrate that NLA, similar to MIP, improves SNR and image quality. It does so consistently in all situations to which it is applied. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 19 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   Analysis of multiple-acquisition SSFP [J].
Bangerter, NK ;
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Gold, GE ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1038-1047
[3]  
Casselman JW, 1996, NEURORADIOLOGY, V38, P278
[4]   Aplasia and hypoplasia of the vestibulocochlear nerve: Diagnosis with MR imaging [J].
Casselman, JW ;
Offeciers, FE ;
Govaerts, PJ ;
Kuhweide, R ;
Geldof, H ;
Somers, T ;
DHont, G .
RADIOLOGY, 1997, 202 (03) :773-781
[5]  
CASSELMAN JW, 1993, AM J NEURORADIOL, V14, P47
[6]  
Haacke E. M., 1999, MAGNETIC RESONANCE I, P914
[7]  
HARGREAVES B, 2002, P ISMRM, P245
[8]  
Hirai T, 2000, JMRI-J MAGN RESON IM, V11, P120, DOI 10.1002/(SICI)1522-2586(200002)11:2<120::AID-JMRI7>3.0.CO
[9]  
2-Q
[10]   Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state [J].
Kellman, P ;
Guttman, MA ;
Herzka, DA ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1076-1080