Temperature-responsive size-exclusion chromatography using poly(N-isopropylacrylamide) grafted silica

被引:41
作者
Lakhiari, H
Okano, T
Nurdin, N
Luthi, C
Descouts, P
Muller, D
Jozefonvicz, J
机构
[1] Univ Paris 13, CNRS URA 502, Lab Rech Macromol, Inst Galilee, F-93430 Villetaneuse, France
[2] Tokyo Womens Med Coll, Shinjuku Ku, Tokyo 162, Japan
[3] Univ Geneva, Appl Phys Grp, CH-1211 Geneva, Switzerland
来源
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS | 1998年 / 1379卷 / 03期
关键词
silica; poly(N-isopropylacrylamide); high performance size-exclusion chromatography;
D O I
10.1016/S0304-4165(97)00110-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Silica-based packing materials induce non-specific interactions with proteins in aqueous media because of the nature of their surface, mainly silanol groups. Therefore, the silica surface has to be modified in order to be used as stationary phase for the High Performance Size-Exclusion Chromatography (HPSEC) of proteins, For this purpose, porous silica beads were coated with hydrophilic polymer gels (dextrans of different molecular weights) carrying a calculated amount of diethylaminoethyl groups (DEAE). Actually, as shown by HPSEC, these dextran modified supports minimize non-specific adsorption for proteins and pullulans in aqueous solution. Then, in order to change the pore size in response to temperature, temperature responsive polymer of poly(N-isopropylacrylamide) (PIPAAm) was introduced into the surface of dextran-DEAE on porous silica beads. The structure of these supports before and after modification was alternately studied by Scanning Electronic Microscopy (SEM) and Scanning Force Microscopy (SFM), An adsorption of radiolabelled albumin was performed to complete our study. Silica modifications by dextran-DEAE and PIPAAm improve the neutrality of the support and minimize the non-specific interactions between the solid support and proteins in solution. At low temperature, the support having PIPAAm exhibits a high resolution domain in HPSEC and finally permits a better resolution of proteins and pullulans. At higher temperature, hydrophobic properties of PIPAAm produce interactions with some proteins and trigger off a slight delay of their elution time. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 31 条
[11]   HIGH-PERFORMANCE AFFINITY-CHROMATOGRAPHY OF INSULIN ON COATED SILICA GRAFTED WITH SIALIC-ACID [J].
LAKHIARI, H ;
LEGENDRE, E ;
MULLER, D ;
JOZEFONVICZ, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 664 (01) :163-173
[12]   INTERACTION MECHANISMS BETWEEN INSULIN AND N-ACETYLNEURAMINIC ACID IN AFFINITY-CHROMATOGRAPHY [J].
LAKHIARI, H ;
MULLER, D ;
JOZEFONVICZ, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 711 (01) :93-103
[13]   COATED SILICA AND ITS BEHAVIOR IN DYE-AFFINITY CHROMATOGRAPHY [J].
MISLOVICOVA, D ;
NOVAK, I ;
PASTEKA, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01) :9-16
[14]   INFLUENCE OF HYDROPHILIC AND HYDROPHOBIC DOMAINS ON WATER WETTABILITY OF 2-HYDROXYETHYL METHACRYLATE-STYRENE COPOLYMERS [J].
OKANO, T ;
KATAYAMA, M ;
SHINOHARA, I .
JOURNAL OF APPLIED POLYMER SCIENCE, 1978, 22 (02) :369-377
[15]   A NOVEL RECOVERY-SYSTEM FOR CULTURED-CELLS USING PLASMA-TREATED POLYSTYRENE DISHES GRAFTED WITH POLY(N-ISOPROPYLACRYLAMIDE) [J].
OKANO, T ;
YAMADA, N ;
SAKAI, H ;
SAKURAI, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (10) :1243-1251
[16]   POLYMERS IMMOBILIZED ON SILICA-GELS AS STATIONARY PHASES FOR LIQUID-CHROMATOGRAPHY [J].
PETRO, M ;
BEREK, D .
CHROMATOGRAPHIA, 1993, 37 (9-10) :549-561
[17]   DEXTRAN-GRAFTED SILICA-GEL FOR HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY OF PROTEINS [J].
PETRO, M ;
GEMEINER, P ;
BEREK, D .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) :37-45
[18]   GEL FILTRATION - METHOD FOR DESALTING AND GROUP SEPARATION [J].
PORATH, J ;
FLODIN, P .
NATURE, 1959, 183 (4676) :1657-1659
[19]   GLYCEROLPROPYLSILANE BONDED PHASES IN STERIC EXCLUSION CHROMATOGRAPHY OF BIOLOGICAL MACROMOLECULES [J].
REGNIER, FE ;
NOEL, R .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1976, 14 (07) :316-320
[20]  
ROUMELIOTIS P, 1981, HIGH PERFORMANCE CHR, P71