Low-dose high-resolution CT of the chest in children and young adults:: Dose, cooperation, artifact incidence, and image quality

被引:131
作者
Lucaya, J
Piqueras, J
García-Peña, P
Enríquez, G
García-Macías, M
Sotil, J
机构
[1] HIM, Hosp Gen Valle Hebron, Dept Radiol, Barcelona 08035, Spain
[2] Hosp Gen Valle Hebron, Inst Diagnost Imaging, Barcelona 08035, Spain
[3] Hosp Gen Valle Hebron, Radiat Protect Dept, Barcelona 08035, Spain
关键词
D O I
10.2214/ajr.175.4.1750985
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The radiation dose, artifact incidence, and image quality of high-resolution chest CT examinations performed with standard and low doses and patient cooperation were investigated in children and young adults. SUBJECTS AND METHODS, Three successive controlled studies were conducted in different groups of children and young adults, totaling 203 patients. Dosimetry of high-resolution CT was pel formed at 180, 50, and 34 mAs in three groups of 25 patients. Streak artifact incidence using alternating 50- and 34-mAs slices was assessed and correlated with patient compliance with breath-holding commands in 44 children. Image quality was evaluated in scans obtained with 34 versus 180 mAs in cooperative patients (n = 42) and in scans obtained with 50 versus 180 mAs in noncooperative patients (n = 42). Artifacts and image quality were assessed by controlled repeated interpretations. RESULTS. Radiation dose was 5.4 +/- 1.6 mSv for 180 mAs, 1.5 +/- 0.5 mSv for 50 mAs, and 1.1 +/- 0.3 mSv for 34 mAs. Cooperation was obtained in 66% of the patients. Artifacts were more frequently seen in scans of noncooperative patients (30%) and in 34-mAs scans (47%); the highest incidence was found using 34 mAs in noncooperative patients (60%, p = 0.02). No differences in image quality scores were seen in scans obtained with 50 mAs versus those obtained with 180 mAs in noncooperative patients (p < 0.05), and small differences were found in scans obtained with 33 mAs versus those obtained with 180 mAs in cooperative patients for fissures (p = 0.005) and peripheral structures (p = 0.02). CONCLUSION, Low-dose high-resolution CT provided a significant reduction in radiation dose (72% for 50 mAs and 80% for 34 mAs) and good-quality images of the lung when performed with 50 mAs in noncooperative and 34; mAs in cooperative pediatric and young adult patients.
引用
收藏
页码:985 / 992
页数:8
相关论文
共 28 条
[1]   FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST [J].
AMBROSINO, MM ;
GENIESER, NB ;
ROCHE, KJ ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1994, 24 (01) :6-10
[2]   CHARACTERISTICS AND CONTROL OF CONTRAST IN CT [J].
BARNES, JE .
RADIOGRAPHICS, 1992, 12 (04) :825-837
[3]   Accuracy of high-resolution CT in diagnosing lung diseases [J].
Bonelli, FS ;
Hartman, TE ;
Swensen, SJ ;
Sherrick, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (06) :1507-1512
[4]  
Cohen J., 1998, Statistical Power Analysis for the Behavioral Sciences, V2nd
[5]  
CURRY TS, 1984, INTRO PHYSICS DIAGNO, P320
[6]   PEDIATRIC-PATIENT EXPOSURES FROM CT EXAMINATIONS - GE CT/T 9800 SCANNER [J].
FEARON, T ;
VUCICH, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) :805-809
[7]   LARGE SAMPLE VARIANCE OF KAPPA IN THE CASE OF DIFFERENT SETS OF RATERS [J].
FLEISS, JL ;
NEE, JCM ;
LANDIS, JR .
PSYCHOLOGICAL BULLETIN, 1979, 86 (05) :974-977
[8]   An approach for the estimation of effective radiation dose at CT in pediatric patients [J].
Huda, W ;
Atherton, JV ;
Ware, DE ;
Cumming, WA .
RADIOLOGY, 1997, 203 (02) :417-422
[9]   GENERAL METHODOLOGY FOR ANALYSIS OF EXPERIMENTS WITH REPEATED MEASUREMENT OF CATEGORICAL DATA [J].
KOCH, GG ;
LANDIS, JR ;
FREEMAN, JL ;
FREEMAN, DH ;
LEHNEN, RG .
BIOMETRICS, 1977, 33 (01) :133-158
[10]  
KUHN JP, 1993, RADIOL CLIN N AM, V31, P533