Transcatheter occlusion of patent ductus arteriosus using a new angled Amplatzer duct occluder: Initial clinical experience

被引:37
作者
Masura, J [1 ]
Gavora, P [1 ]
Podnar, T [1 ]
机构
[1] Univ Childrens Hosp, Childrens Cardiac Ctr, Bratislava, Slovakia
关键词
Amplatzer duct occluder; patent ductus arteriosus; transcatheter occlusion;
D O I
10.1002/ccd.10413
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
In the present study, we report the initial clinical experience with the new angled Amplatzer duct occluder (ADO) for the percutaneous closure of patent ductus arteriosus (PDA). Percutaneous closure of PDA using standard ADO in infants and in patients with small PDA ampulla is difficult, or even impossible, due to protrusion of the aortic disk into the descending thoracic aorta. The aortic disk of an angled ADO is angled at 32degrees to the body of the device and concave toward the aorta to prevent protrusion of the disk into the aorta. Percutaneous closure of PDA was attempted in nine patients with a median age of 5.2 years (range, 0.5-12.7) and median weight of 20 kg (range, 4.9-55). Selection of the occluder and the implantation technique were similar to the standard ADO. The minimal PDA diameter ranged from 2.1 to 3.7 mm (median, 2.5 mm). Occluders were successfully implanted in all patients. Immediate complete PDA closure was achieved in all patients. There were no complications. The new angled ADO is a safe and effective device for PDA closure, particularly suitable for infants and patients with small PDA ampulla. Further studies and long-term follow-up are necessary to confirm our initial experience.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 16 条
[1]
The Amplatzer duct occluder: Experience in 209 patients [J].
Bilkis, AA ;
Alwi, M ;
Hasri, S ;
Haifa, AL ;
Geetha, K ;
Rehman, MA ;
Hasanah, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) :258-261
[2]
Aortic obstruction caused by device occlusion of patent arterial duct [J].
Duke, C ;
Chan, KC .
HEART, 1999, 82 (01) :109-111
[3]
Faella HJ, 2000, CATHETER CARDIO INTE, V51, P50, DOI 10.1002/1522-726X(200009)51:1<50::AID-CCD11>3.0.CO
[4]
2-6
[5]
Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder [J].
Fischer, G ;
Stieh, J ;
Uebing, A ;
Grabitz, R ;
Kramer, HH .
HEART, 2001, 86 (04) :444-447
[6]
RESULTS OF ANTEROGRADE TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING SINGLE OR MULTIPLE GIANTURCO COILS [J].
HIJAZI, ZM ;
GEGGEL, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (09) :925-929
[7]
Transcatheter closure of large patent ductus arteriosus (>=4 mm) with multiple Gianturco coils: Immediate and mid-term results [J].
Hijazi, ZM ;
Geggel, RL .
HEART, 1996, 76 (06) :536-540
[8]
Experimental evaluation of a modified amplatzer duct occluder [J].
Kong, HF ;
Gu, XP ;
Bass, JL ;
Titus, J ;
Urness, M ;
Kim, TH ;
Hunter, DW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) :571-576
[9]
ANGIOGRAPHIC CLASSIFICATION OF THE ISOLATED, PERSISTENTLY PATENT DUCTUS-ARTERIOSUS AND IMPLICATIONS FOR PERCUTANEOUS CATHETER OCCLUSION [J].
KRICHENKO, A ;
BENSON, LN ;
BURROWS, P ;
MOES, CAF ;
MCLAUGHLIN, P ;
FREEDOM, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) :877-880
[10]
A STUDY OF THE ANGLE FORMED BY THE DUCTUS ARTERIOSUS WITH THE DESCENDING THORACIC AORTA [J].
MANCINI, AJ .
ANATOMICAL RECORD, 1951, 109 (03) :535-539