In-situ irradiation test of mica substrate bolometer at the JMTR reactor for the ITER diagnostics

被引:13
作者
Nishitani, T [1 ]
Shikama, T
Reichle, R
Hodgson, ER
Ishitsuka, E
Kasai, S
Yamamoto, S
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
[2] Tohoku Univ, Aoba Ku, Sendai, Miyagi 9800813, Japan
[3] CE Cadarache, CEA Fus, F-13108 St Paul Les Durance, France
[4] CIEMAT Fus Assoc, Madrid 28040, Spain
关键词
bolometer; mica substrate; irradiation; ITER; diagnostics; Japan Materials Testing Reactor;
D O I
10.1016/S0920-3796(02)00126-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Irradiation tests of a mica substrate bolometer were carried out at the Japan Materials Testing Reactor up to the fast neutron fluence of 0.1 dpa. A performance of the bolometer was investigated during the irradiation. Significant increase of the meander resistance from 275 to 446 Omega was observed in the fast neutron fluence of 0.06 dpa. In the post-irradiation examination (PIE), it was confirmed that the gold meander contained 46% mercury which was produced by the nuclear transmutation reaction of (197)Au(n, gamma) (198)Au --> (198)Hg + beta(-). The bolometer sensitivity was measured by the change of the meander resistance for the input power. The sensitivity decreased slightly at constant reactor power. There was not significant change in the bolometer response time. During the cool down phase of the first cycle all connections went open circuit. Some recovered on start-up of the second cycle, however, all connections went open circuit again near the end of the second cycle. They were not recovered any more at the third cycle. Breaks of the gold meander were observed in the PIE. The use of gold meanders might be problematic in ITER. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 7 条
[1]   A LOW-NOISE HIGHLY INTEGRATED BOLOMETER ARRAY FOR ABSOLUTE MEASUREMENT OF VUV AND SOFT X-RADIATION [J].
MAST, KF ;
VALLET, JC ;
ANDELFINGER, C ;
BETZLER, P ;
KRAUS, H ;
SCHRAMM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03) :744-750
[2]  
Nakagawa T, 1995, J NUCL SCI TECHNOL, V32, P1259, DOI [10.3327/jnst.32.1259, 10.1080/18811248.1995.9731849]
[3]  
NARUI M, IN PRESS J NUCL MAT
[4]   Neutron irradiation tests on diagnostic components at JAERI [J].
Nishitani, T ;
Shikama, T ;
Fukao, M ;
Reichle, R ;
Sugie, T ;
Kakuta, T ;
Kasai, S ;
Snider, R ;
Yamamoto, S .
FUSION ENGINEERING AND DESIGN, 2001, 56-57 :905-909
[5]  
Reichle R, 1996, DIAGNOSTICS FOR EXPERIMENTAL THERMONUCLEAR FUSION REACTORS, P559
[6]  
REICHLE R, COMMUNICATION
[7]  
REICHLE R, 1998, DIAGNOSTICS EXPT THE, V2, P389