Analytical procedures for improved trace element detection limits in polar ice from Arctic Canada using ICP-SMS

被引:64
作者
Krachler, M
Zheng, J
Fisher, D
Shotyk, W
机构
[1] Heidelberg Univ, Inst Environm Geochem, D-69120 Heidelberg, Germany
[2] Geol Survey Canada, Terrain Sci Div, Ottawa, ON, Canada
关键词
trace elements; ice; ICP-MS; Arctic; scandium; thallium;
D O I
10.1016/j.aca.2004.09.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analytical procedures have been developed for the reliable determination of 19 trace elements (Ag, Al, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Pb, Rb, Sb, Sc, Sr, TI, U, V, Zn) in ice samples at pg g(-1) and fg g(-1) concentrations using ICP-sector field mass spectrometry (ICP-SMS). Concentrations of most elements in the high purity water and doubly distilled HNO3 employed were distinctly lower than previously reported values. The accuracy of the results was carefully evaluated using the certified water reference material SLRS-4. Contributions of unwanted trace elements due to acidification of the ice samples (0.5% HNO3) to the total element budget amounted to only 0.001 pg g(-1) for Bi, 0.34 pg g(-1) for Cr, 0.2 pg g(-1) for Fe, 0.004 pg g(-1) for Pb, 0.00015 pg g(-1) for U and 0.0025 pg g(-1) for V: compared to the concentrations of the metals in ice these are negligible. The use of a detergent (0.05%) in the rinsing solution (0.5% HNO3 helped to reduce memory effects by 59-98%, depending on the element considered; this resulted in shorter washing times between samples (i.e. 1 min) and improved analysis time. Adopting strict clean room procedures, the detection limit for Pb (0.06 pg g(-1)) is a factor of ten lower than the current state-of-the-art. Compared to previous studies, the improved LODs obtained here for other trace elements amount to 2 x (Ag), 4 x (Sb), 5 x (Ba), 6 x (Cu, Mn, U), 9 x (Bi), 13 x (Cd), 18 x (Fe) and 21 x (V). The developed analytical protocols were successfully applied to the determination of selected trace elements in age-dated ice samples from the Canadian High Arctic. The toxic trace element TI (median: 0. 16 pg g(-1); range: 0.03-1.32 pg g(-1)) and the lithogenic reference element Sc (0.53 pg g-(1`); 0.06-2.9 pg g(-1)) have been determined in a polar ice core for the first time. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 15 条
[1]   Greenland snow evidence of large scale atmospheric contamination for platinum, palladium, and rhodium [J].
Barbante, C ;
Veysseyre, A ;
Ferrari, C ;
Van de Velde, K ;
Morel, C ;
Capodaglio, G ;
Cescon, P ;
Scarponi, G ;
Boutron, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (05) :835-839
[2]   Seasonal variations in nickel and vanadium in Mont Blanc snow and ice dated from the 1960s and 1990s [J].
Barbante, C ;
Boutron, C ;
Moreau, AL ;
Ferrari, C ;
Van de Velde, K ;
Cozzi, G ;
Turetta, C ;
Cescon, P .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (06) :960-966
[3]   Trace element determination in alpine snow and ice by double focusing inductively coupled plasma mass spectrometry with microconcentric nebulization [J].
Barbante, C ;
Cozzi, G ;
Capodaglio, G ;
van de Velde, K ;
Ferrari, C ;
Boutron, C ;
Cescon, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1433-1438
[4]   Post-World War II uranium changes in dated Mont Blanc ice and snow [J].
Barbante, C ;
Van De Velde, K ;
Cozzi, G ;
Capodaglio, G ;
Cescon, P ;
Planchon, F ;
Hong, SM ;
Ferrari, C ;
Boutron, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (20) :4026-4030
[5]   AN IMPROVED METHOD FOR DECONTAMINATING POLAR SNOW OR ICE CORES FOR HEAVY-METAL ANALYSIS [J].
CANDELONE, JP ;
HONG, SM ;
BOUTRON, CF .
ANALYTICA CHIMICA ACTA, 1994, 299 (01) :9-16
[6]   Determination of Ir and Pt down to the sub-femtogram per gram level in polar ice by ICP-SFMS using preconcentration and a desolvation system [J].
Gabrielli, P ;
Varga, A ;
Barbante, C ;
Boutron, C ;
Cozzi, G ;
Gaspari, V ;
Planchon, F ;
Cairns, W ;
Hong, SM ;
Ferrari, C ;
Capodaglio, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) :831-837
[7]   Accuracy of continuous ice-core trace-element analysis by inductively coupled plasma sector field mass spectrometry [J].
Knüsel, S ;
Piguet, DE ;
Schwikowski, M ;
Gäggeler, HW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (10) :2267-2273
[8]   Novel calibration procedure for improving trace element determinations in ice and water samples using ICP-SMS [J].
Krachler, M ;
Zheng, J ;
Fisher, D ;
Shotyk, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :1017-1019
[9]  
KRACHLER M, IN PRESS ANAL CHEM
[10]   Continuous ice-core chemical analyses using inductively Coupled Plasma Mass Spectrometry [J].
McConnell, JR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :7-11