Simultaneous Use of Implantable Cardioverter-Defibrillators and Left Ventricular Assist Devices in Patients With Severe Heart Failure

被引:38
作者
Kuehne, Michael [1 ]
Sakumura, Michaela [1 ]
Reich, Stephen Scott [1 ]
Sarrazin, Jean-Francois [1 ]
Wells, Darryl [1 ]
Chalfoun, Nagib [1 ]
Crawford, Thomas [1 ]
Boonyapisit, Warangkna [1 ]
Horwood, Laura [1 ]
Chugh, Aman [1 ]
Good, Eric [1 ]
Jongnarangsin, Krit [1 ]
Bogun, Frank [1 ]
Oral, Hakan [1 ]
Morady, Fred [1 ]
Pagani, Francis [2 ]
Pelosi, Frank, Jr. [1 ]
机构
[1] Univ Michigan Hlth Syst, Div Cardiovasc Med, Ann Arbor, MI USA
[2] Univ Michigan Hlth Syst, Sect Cardiac Surg, Ann Arbor, MI USA
关键词
CONTRACTION-EXCITATION FEEDBACK; ARRHYTHMIAS; SUPPORT; THERAPIES;
D O I
10.1016/j.amjcard.2009.09.044
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
More patients who are receiving therapy with a left ventricular assist device (LVAD) also have an implantable cardioverter-defibrillator (ICD). The aim of the present study was to describe the outcomes and device interactions of simultaneous therapy with an ICD and a LVAD. We evaluated 76 patients with class IV heart failure (age 52 +/- 12 years, left ventricular ejection fraction 0.13 +/- 0.05%, 88% men, 61% nonischemic cardiomyopathy) with both an ICD and a LVAD. The median follow-up with both devices was 156 days. A LVAD with a pulsatile and continuous flow pump was used in 53 (70%) and 23 (30%) patients, respectively. Of the 76 patients, 12 (16%) received a total of 54 ICD therapies. Of the ICD therapies, 88% were appropriate. Of the 76 patients, 55 (72%) underwent heart transplantation a median of 146 days after LVAD implantation. Twelve patients (16%) died during simultaneous ICD and LVAD therapy. Interactions between the LVAD and ICD occurred in 2 patients (2.7%) with continuous flow pumps (Heart Mate II). In both cases, telemetry failure occurred after LVAD implantation with 2 different models of ICDs from the same manufacturer. No ICD therapies occurred because of device-related interactions. In conclusion, simultaneous ICD and LVAD therapy in patients with severe congestive heart failure is safe and clinically feasible. Interactions between the devices are uncommon and appear limited to specific models of ICDs. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;105:378 382)
引用
收藏
页码:378 / 382
页数:5
相关论文
共 20 条
[1]
Clinical definition and epidemiology of advanced heart failure [J].
Adams, KF ;
Zannad, F .
AMERICAN HEART JOURNAL, 1998, 135 (06) :S204-S215
[2]
Incidence of Ventricular Arrhythmias in Patients on Long-term Support With a Continuous-flow Assist Device (HeartMate II) [J].
Andersen, Mads ;
Videbaek, Regitze ;
Boesgaard, Soren ;
Sander, Kare ;
Hartsen, Peter B. ;
Gustafsson, Finn .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (07) :733-735
[3]
Electromagnetic interaction between an axial left ventricular assist device and an implantable cardioverter defibrillator [J].
Bakhtiary, Farhad ;
Therapidis, Panagiotis ;
Scherer, Mirela ;
Dzemali, Omer ;
Moritz, Anton ;
Kleine, Peter .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05) :1380-1381
[4]
Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[5]
Overcoming Electromagnetic Interference by LVADs on ICD Function by Shielding the ICD Programmer Wand and Extension Cable [J].
Biviano, Angelo ;
Mancini, Donna ;
Naka, Yoshifumi ;
Arellano, Jerry ;
Garan, Hasan .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07) :945-948
[6]
Deng MC, 1999, AM J CARDIOL, V83, p158D
[7]
Left Ventricular Mechanical Assist Devices and Cardiac Device Interactions: An Observational Case Series [J].
Foo, David ;
Walker, Bruce D. ;
Kuchar, Dennis L. ;
Thorburn, Charles W. ;
Tay, Andre ;
Hayward, Christopher S. ;
Macdonald, Peter ;
Keogh, Anne ;
Kotlyar, Eugene ;
Spratt, Philip ;
Jansz, Paul .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07) :879-887
[8]
Frequency and causes of implantable cardioverter-defibrillator therapies: Is device therapy proarrhythmic? [J].
Germano, JJ ;
Reynolds, M ;
Essebag, V ;
Josephson, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (08) :1255-1261
[9]
Medical progress - Implantable left ventricular assist devices [J].
Goldstein, DJ ;
Oz, MC ;
Rose, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (21) :1522-1533
[10]
Prolonged repolarization after ventricular assist device support is associated with arrhythmias in humans with congestive heart failure [J].
Harding, JD ;
Piacentino, V ;
Rothman, S ;
Chambers, S ;
Jessup, M ;
Margulies, KB .
JOURNAL OF CARDIAC FAILURE, 2005, 11 (03) :227-232