Mechanical effects of airway humidification devices in difficult to wean patients

被引:44
作者
Girault, C [1 ]
Breton, L [1 ]
Richard, JC [1 ]
Tamion, F [1 ]
Vandelet, P [1 ]
Aboab, J [1 ]
Leroy, J [1 ]
Bonmarchand, G [1 ]
机构
[1] Univ Rouen, Hop Charles Nicolle, Med Intens Care Dept, Rouen, France
关键词
heat and moisture exchanger; heated humidifier; work of breathing; pressure support ventilation; weaning; PRESSURE-SUPPORT VENTILATION; MOISTURE EXCHANGERS; MINUTE VENTILATION; HEATED HUMIDIFIERS; ASSIST-CONTROL; WORK; PEEP; EXTUBATION; TRIALS;
D O I
10.1097/01.CCM.0000063284.92122.0E
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the influence of airway humidification devices on the efficacy of ventilation in difficult to wean patients. Design: A prospective, randomized, controlled physiologic study. Setting: A 22-bed medical intensive care unit in a university hospital. Patients: Chronic respiratory failure patients. Interventions: Performances of a heated humidifier and a heat and moisture exchanger were evaluated on diaphragmatic muscle activity, breathing pattern, gas exchange, and respiratory comfort during weaning from mechanical ventilation by using pressure support ventilation. Eleven patients with chronic respiratory failure were submitted to four pressure support ventilation sequences by using the heated humidifier and the heat and moisture exchanger at two different levels of pressure support ventilation (7 and 15 cm H2O). Measurement and Main Results: Compared with the heated humidifier and regardless of the pressure support ventilation level used, the heat and moisture exchanger significantly increased all of the inspiratory effort variables (inspiratory work of breathing expressed in J/L and J/min, pressure time product, changes in esophageal pressure, and transdiaphragmatic pressure; p <.05) and dynamic intrinsic positive end-expiratory pressure (p <.05). Similarly, the heat and moisture exchanger produced a significant increase in Paco(2) (p <.01) responsible for severe respiratory acidosis (p <.05), which was insufficiently compensated for despite a significant increase in minute ventilation (p <.05). This resulted in respiratory discomfort for all patients with the heat and moisture exchanger (p <.01). Adverse effects were partially counterbalanced by increasing the pressure support ventilation level with the heat and moisture exchanger by greater than or equal to8 cm H2O. Conclusions: The type of airway humidification device used may negatively influence the mechanical efficacy of ventilation and, unless the pressure support ventilation level is considerably increased, the use of a heat and moisture exchanger should not be recommended in difficult or potentially difficult to wean patients with chronic respiratory failure. (Crit Care Med 2003; 31:1306-1311).
引用
收藏
页码:1306 / 1311
页数:6
相关论文
共 32 条
[1]   COMPONENTS OF THE WORK OF BREATHING AND IMPLICATIONS FOR MONITORING VENTILATOR-DEPENDENT PATIENTS [J].
BANNER, MJ ;
JAEGER, MJ ;
KIRBY, RR .
CRITICAL CARE MEDICINE, 1994, 22 (03) :515-523
[2]   EVALUATION OF HUMAN DIAPHRAGM FATIGUE [J].
BELLEMARE, F ;
GRASSINO, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (05) :1196-1206
[3]  
Branson RD, 1996, Respir Care, V41, P736
[4]   COMPARISON OF 3 METHODS OF GRADUAL WITHDRAWAL FROM VENTILATORY SUPPORT DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
RAUSS, A ;
BENITO, S ;
CONTI, G ;
MANCEBO, J ;
REKIK, N ;
GASPARETTO, A ;
LEMAIRE, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :896-903
[5]   INSPIRATORY PRESSURE SUPPORT COMPENSATES FOR THE ADDITIONAL WORK OF BREATHING CAUSED BY THE ENDOTRACHEAL-TUBE [J].
BROCHARD, L ;
RUA, F ;
LORINO, H ;
LEMAIRE, F ;
HARF, A .
ANESTHESIOLOGY, 1991, 75 (05) :739-745
[6]   SIMPLE METHODS OF ESTIMATING OXYGEN CONSUMPTION AND EFFICIENCY OF THE MUSCLES OF BREATHING [J].
CAMPBELL, EJM ;
WESTLAKE, EK ;
CHERNIACK, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1957, 11 (02) :303-308
[7]   USE OF HEAT AND MOISTURE EXCHANGING (HME) FILTERS IN MECHANICALLY VENTILATED ICU PATIENTS - INFLUENCE ON AIRWAY FLOW-RESISTANCE [J].
CHIARANDA, M ;
VERONA, L ;
PINAMONTI, O ;
DOMINIONI, L ;
MINOJA, G ;
CONTI, G .
INTENSIVE CARE MEDICINE, 1993, 19 (08) :462-466
[8]   EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS [J].
CONTI, G ;
DEBLASI, RA ;
ROCCO, M ;
PELAIA, P ;
ANTONELLI, M ;
BUFI, M ;
MATTIA, C ;
GASPARETTO, A .
INTENSIVE CARE MEDICINE, 1990, 16 (07) :441-443
[9]   Influence of airway management on ventilator-associated pneumonia - Evidence from randomized trials [J].
Cook, D ;
De Jonghe, B ;
Brochard, L ;
Brun-Buisson, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 279 (10) :781-787
[10]  
DREYFUSS D, 1995, AM J RESP CRIT CARE, V151, P986