Reliability of Visual Assessment of Global and Segmental Left Ventricular Function: A Multicenter Study by the Israeli Echocardiography Research Group

被引:56
作者
Blondheim, David S. [1 ]
Beeri, Ronen [2 ]
Feinberg, Micha S. [3 ]
Vaturi, Mordehay [4 ]
Shimoni, Sarah [5 ]
Fehske, Wolfgang [6 ]
Sagie, Alik [4 ]
Rosenmann, David [7 ]
Lysyansky, Peter [8 ]
Deutsch, Lisa [8 ]
Leitman, Marina [9 ]
Kuperstein, Rafael [3 ]
Hay, Ilan [3 ]
Gilon, Dan [2 ]
Friedman, Zvi [8 ]
Agmon, Yoram [10 ]
Tsadok, Yossi [11 ]
Liel-Cohen, Noah [12 ]
机构
[1] Hillel Yaffe Med Ctr, Hadera, Israel
[2] Hadassah Univ Hosp, IL-91120 Jerusalem, Israel
[3] Sheba Med Ctr, Tel Aviv, Israel
[4] Rabin Med Ctr, Petah Tiqwa, Israel
[5] Kaplan Med Ctr, Rehovot, Israel
[6] St Vinzenz Hosp, Cologne, Germany
[7] Shaare Zedek Med Ctr, Jerusalem, Israel
[8] GE Healthcare, Haifa, Israel
[9] Assaf Harofeh Med Ctr, Zerifin, Israel
[10] Rambam Med Ctr, Haifa, Israel
[11] Ben Gurion Univ Negev, IL-84105 Beer Sheva, Israel
[12] Soroka Univ, Med Ctr, Beer Sheva, Israel
关键词
Echocardiography; Variability; Reliability; Wall motion; Ejection fraction; DOBUTAMINE STRESS ECHOCARDIOGRAMS; ACUTE MYOCARDIAL-INFARCTION; AMERICAN-HEART-ASSOCIATION; EJECTION FRACTION; COMPUTED-TOMOGRAPHY; OF-CARDIOLOGY; WALL-MOTION; REPRODUCIBILITY; AGREEMENT; STATEMENT;
D O I
10.1016/j.echo.2009.12.020
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: The purpose of this multicenter study was to determine the reliability of visual assessments of segmental wall motion (WM) abnormalities and global left ventricular function among highly experienced echocardiographers using contemporary echocardiographic technology in patients with a variety of cardiac conditions. Methods: The reliability of visual determinations of left ventricular WM and global function was calculated from assessmentsmade by 12 experienced echocardiographers on 105 echocardiograms recorded using contemporary echocardiographic equipment. Ten studies were reread independently to determine intraobserver reliability. Results: Interobserver reliability for visual differentiation between normal, hypokinetic, and akinetic segments had an intraclass correlation coefficient of 0.70. The intraclass correlation coefficient for dichotomizing segments into normal versus other abnormal was 0.63, for hypokinetic versus other scores was 0.26, and for akinetic versus other scores was 0.58. Similar results were found for intraobserver reliability. Interobserver reliability for WM score index was 0.84 and for left ventricular ejection fraction was 0.78. Similar values were obtained for the intraobserver reliability of WM score index and ejection fraction. Compared to angio-graphic data, the accuracy of segmental WM assessments was 85%, and correct determination of the culprit artery was achieved in 59% of patients with myocardial infarctions. Conclusion: Among experienced readers using contemporary echocardiographic equipment, interobserver and intraobserver reliability was reasonable for the visual quantification of normal and akinetic segments but poor for hypokinetic segments. Reliability was good for the visual assessment of global left ventricular function by WM score index and ejection fraction. (J Am Soc Echocardiogr 2010;23:258-64.)
引用
收藏
页码:258 / 264
页数:7
相关论文
共 25 条
[1]
[Anonymous], 1993, INTRO BOOTSTRAP
[2]
Reproducibility of wall motion score and its correlation with left ventricular ejection fraction in patients with acute myocardial infarction [J].
Badano, L ;
Stoian, J ;
Cervesato, E ;
Bosimini, E ;
Gentile, F ;
Giannuzzi, P ;
Heyman, J ;
Lucci, D ;
Maggioni, AP ;
Piazza, R ;
Nicolosi, GL .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (07) :855-&
[3]
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[4]
Cardiac multidetector-row computed tomography in patients with unstable angina [J].
Dirksen, MS ;
Jukema, JW ;
Bax, JJ ;
Lamb, HJ ;
Boersma, E ;
Tuinenburg, JC ;
Geleijns, J ;
van der Wall, EE ;
de Roos, A .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (04) :457-461
[5]
Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography - A multicenter comparison of methods [J].
Hoffmann, R ;
von Bardeleben, S ;
Kasprzak, JD ;
Borges, AC ;
ten Cate, F ;
Firschke, C ;
Lafitte, S ;
Al-Saadi, N ;
Kuntz-Hehner, S ;
Horstick, G ;
Greis, C ;
Engelhardt, M ;
Vanoverschelde, JL ;
Becher, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) :121-128
[6]
Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms [J].
Hoffmann, R ;
Lethen, H ;
Marwick, T ;
Arnese, M ;
Fioretti, P ;
Pingitore, A ;
Picano, E ;
Buck, T ;
Erbel, R ;
Flachskampf, FA ;
Hanrath, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) :330-336
[7]
Refinements in stress echocardiographic techniques improve inter-institutional agreement in interpretation of dobutamine stress echocardiograms [J].
Hoffmann, R ;
Marwick, TH ;
Poldermans, D ;
Lethen, H ;
Ciani, R ;
van der Meer, P ;
Tries, HP ;
Gianfagna, P ;
Floretti, P ;
Bax, JJ ;
Katz, MA ;
Erbel, R ;
Hanrath, P .
EUROPEAN HEART JOURNAL, 2002, 23 (10) :821-829
[8]
Comparison of different echocardiographic methods with radionuclide imaging for measuring left ventricular ejection fraction during acute myocardial infarction treated by thrombolytic therapy [J].
Jensen-Urstad, K ;
Bouvier, F ;
Hojer, J ;
Ruiz, H ;
Hulting, J ;
Samad, B ;
Thorstrand, C ;
Jensen-Urstad, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) :538-544
[9]
Echocardiography in heart failure - Applications, utility, and new horizons [J].
Kirkpatrick, James N. ;
Vannan, Mani A. ;
Narula, Jagat ;
Lang, Roberto M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (05) :381-396
[10]
How accurate is visual assessment of synchronicity in myocardial motion?: An in vitro study with computer-simulated regional delay in myocardial motion:: Clinical implications for rest and stress echocardiography studies [J].
Kvitting, JPE ;
Wigström, L ;
Strotmann, JM ;
Sutherland, GR .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (09) :698-705