The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part II:: Tibial site

被引:186
作者
Kousa, P
Järvinen, TLN [1 ]
Vihavainen, M
Kannus, P
Järvinen, M
机构
[1] Tampere Univ, Dept Surg, Tampere 33014, Finland
[2] Tampere Univ Hosp, Tampere, Finland
[3] Jvaskyla Cent Hosp, Dept Surg, Jyvaskyla, Finland
[4] Accident & Trauma Res Ctr, Tampere, Finland
[5] Urho Kaleva Kekkonen Inst Hlth Promot Res, Tampere Res Ctr Sports Med, Tampere, Finland
关键词
D O I
10.1177/03635465030310020501
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tibial fixation is more problematic than femoral fixation in anterior cruciate ligament reconstruction. Hypothesis: There is no difference in initial fixation strength among hamstring tendon graft tibial fixation devices. Study Design: Randomized experimental study. Methods: Each of six devices used to fix 120 quadrupled human semitendinosus-gracilis tendon grafts into porcine tibiae was tested 10 times with a single-cycle load-to-failure test and 10 times with a 1500-cycle loading test. Specimens surviving cyclic loading were subjected to a single-cycle load-to-failure test. Results: Intrafix (1332 N) was the strongest in the single-cycle load-to-failure test, followed by WasherLoc (975 N), tandem spiked washer (769 N), SmartScrew ACL (665 N), BioScrew (612 N), and SoftSilk (471 N). After cyclic-loading tests, Intrafix showed the lowest residual displacement (1.5 mm) and was also strongest (1309 N) in the single-cycle load-to-failure test after the cyclic-loading test, followed by WasherLoc (3.2 mm; 917 N). Conclusion: The Intrafix provided clearly superior strength in the fixation of hamstring tendon grafts to the tibial drill hole. Clinical Relevance: Some caution may be warranted when using the implants that showed increased residual displacement, especially if aggressive rehabilitation is to be used. Preconditioning of the hamstring tendon graft-implant complex before tibial fixation is needed. (C) 2003 American Orthopaedic Society for Sports Medicine.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 20 条
[1]
The effect of screw insertion torque on tendons fixed with spiked washers [J].
Beynnon, BD ;
Meriam, CM ;
Ryder, SH ;
Fleming, BC ;
Johnson, RJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (04) :536-539
[2]
Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[3]
Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque [J].
Brand, JC ;
Pienkowski, D ;
Steenlage, E ;
Hamilton, D ;
Johnson, DL ;
Caborn, DNM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :705-710
[4]
Current trends in anterior cruciate ligament reconstruction Part II. Operative procedures and clinical correlations [J].
Fu, FH ;
Bennett, CH ;
Ma, CB ;
Menetrey, J ;
Lattermann, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :124-130
[5]
Current trends in anterior cruciate ligament reconstruction part 1: Biology and biomechanics of reconstruction [J].
Fu, FH ;
Bennett, CH ;
Lattermann, C ;
Ma, CB .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06) :821-830
[6]
Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction [J].
Giurea, M ;
Zorilla, P ;
Amis, AA ;
Aichroth, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :621-625
[7]
Kousa P, 2001, ARTHROSCOPY, V17, P144, DOI 10.1053/jars.2001.20097
[8]
Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts [J].
Magen, HE ;
Howell, SM ;
Hull, ML .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (01) :35-43
[9]
Malek MM, 1996, AAOS INSTR COURS LEC, V45, P287
[10]
Compaction versus extraction drilling for fixation of the hamstring tendon graft in anterior cruciate ligament reconstruction [J].
Nurmi, JT ;
Järvinen, TLN ;
Kannus, P ;
Sievänen, H ;
Toukosalo, J ;
Järvinen, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (02) :167-173