Peptide electroextraction for direct coupling of in-gel digests with capillary LC-MS/MS for protein identification and sequencing

被引:26
作者
Timperman, AT
Aebersold, R
机构
[1] W Virginia Univ, Dept Chem, Morgantown, WV 26506 USA
[2] Univ Washington, Dept Mol Biotechnol, Seattle, WA 98195 USA
关键词
D O I
10.1021/ac000305w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrophoretic method has been developed for the extraction of peptides following in-gel digests of SDS-PAGE separated proteins. During electroextraction, the peptides are trapped on a strong cation-exchange microcartridge, before analysis by capillary LC-ESI-tandem mass spectrometry, The spectra obtained by tandem mass spectrometry are searched directly against a protein database for identification of the protein from which the peptide originated. By minimizing surface exposure of the peptides during electroextraction, a reduction of the detection limits for protein identification is realized. The performance of the peptide electroextraction was compared directly with the standard extraction method for in-gel protein digests, using a standard dilution series of phosphorylase B and carbonic anhydrase, separated by SDS-PAGE. The lowest gel loading in which phosphorylase B was identified using the standard extraction method was 2.5 ng or 25 fmol, and the lowest gel loading in which phosphorylase B was identified using electroextraction was 1.25 ng or 12.5 fmol. The design of the microextraction cartridge allows for direct interfacing with capillary LC, which is crucial for maintaining low detection limits. Furthermore, this method can be used for high-throughput proteomics since it can be easily multiplexed and requires only voltage control and low pressures (similar to 15 psi) for operation, We believe that peptide electroextraction is a significant advance for identification of proteins separated by one-dimensional or two-dimensional gel electrophoresis, as it can be easily automated and requires less protein than conventional methods.
引用
收藏
页码:4115 / 4121
页数:7
相关论文
共 28 条
[1]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[2]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[3]   One step microelectroelution concentration method for efficient coupling of sodium dodecylsulfate gel electrophoresis and matrix-assisted laser desorption time-of-flight mass spectrometry for protein analysis [J].
Clarke, NJ ;
Li, F ;
Tomlinson, AJ ;
Naylor, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (01) :88-91
[4]   POROUS CERAMIC BED SUPPORTS FOR FUSED-SILICA PACKED CAPILLARY COLUMNS USED IN LIQUID-CHROMATOGRAPHY [J].
CORTES, HJ ;
PFEIFFER, CD ;
RICHTER, BE ;
STEVENS, TS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (08) :446-448
[5]   Bioanalytic applications of mass spectrometry [J].
Costello, CE .
CURRENT OPINION IN BIOTECHNOLOGY, 1999, 10 (01) :22-28
[6]   ISOLATION AND SEQUENCE-ANALYSIS OF PROTEINS FROM MOUSE FOREBRAIN USING TWO-DIMENSIONAL GEL-ELECTROPHORESIS COUPLED TO HIGH-PRESSURE LIQUID EXTRUSION [J].
DEWALD, DB ;
PEARSON, JD .
ANALYTICAL BIOCHEMISTRY, 1989, 180 (02) :340-348
[7]   Enhanced in situ gel digestion of electrophoretically separated proteins with automated peptide elution onto mini reversed-phase columns [J].
Eckerskorn, C ;
Grimm, R .
ELECTROPHORESIS, 1996, 17 (05) :899-906
[8]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[9]   Protein identification using mass spectrometric information [J].
Fenyö, D ;
Qin, J ;
Chait, BT .
ELECTROPHORESIS, 1998, 19 (06) :998-1005
[10]   SINGLE-STEP ELECTROTRANSFER OF REVERSE-STAINED PROTEINS FROM SODIUM DODECYL SULFATE-POLYACRYLAMIDE GEL ONTO REVERSED-PHASE MINICARTRIDGE AND SUBSEQUENT DESALTING AND ELUTION WITH A CONVENTIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY GRADIENT SYSTEM FOR ANALYSIS [J].
FERNANDEZPATRON, C ;
MADRAZO, J ;
HARDY, E ;
MENDEZ, E ;
FRANK, R ;
CASTELLANOSSERRA, L .
ELECTROPHORESIS, 1995, 16 (06) :911-920