Application of HPLC to counting of colored microspheres in determination of regional blood flow

被引:7
作者
Mazoit, JX [1 ]
Le Guen, R [1 ]
Decaux, A [1 ]
Albaladejo, P [1 ]
Samii, K [1 ]
机构
[1] Univ Paris Sud, Fac Med Kremlin Bicetre, Lab Anesthesie, F-94276 Le Kremlin Bicetre, France
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 03期
关键词
high-performance liquid chromatography; internal standard;
D O I
10.1152/ajpheart.1998.274.3.H1041
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Colored microspheres have become popular compared with radioactive microspheres because they do not use radioactivity. However, they suffer from a much greater variability in their determination. We have developed a new method for assaying the dye using highperformance liquid chromatography (HPLC) with internal standard. This technique permits accurate determination of less than or equal to 400 spheres in rat blood, heart, kidney, Liver, and brain with a relative error [coefficient of variation (CV)] <10%. To date, only three colors (white, yellow, and red) may be used because, of the five colors tested, one (violet) served as internal standard and another (blue) exhibited marked degradation during extraction. Compared with the classical spectrophotometric technique, HPLC allows a three to five times improvement in reproducibility with a relative error significantly lower (P < 0.01) than with direct spectrophotometry. Although this new technique appears to be more time consuming than the classical method, its use seems to be preferable because of the improvement in measurement sensitivity.
引用
收藏
页码:H1041 / H1047
页数:7
相关论文
共 15 条
[1]
ARMITAGE P, 1994, STAT METHODS MED RES, P115
[2]
QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES [J].
AUSTIN, RE ;
HAUCK, WW ;
ALDEA, GS ;
FLYNN, AE ;
COGGINS, DL ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :H280-H288
[3]
VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS [J].
BASSINGTHWAIGHTE, JB ;
MALONE, MA ;
MOFFETT, TC ;
KING, RB ;
LITTLE, SE ;
LINK, JM ;
KROHN, KA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01) :H184-H193
[4]
FRACTAL NATURE OF REGIONAL MYOCARDIAL BLOOD-FLOW HETEROGENEITY [J].
BASSINGTHWAIGHTE, JB ;
KING, RB ;
ROGER, SA .
CIRCULATION RESEARCH, 1989, 65 (03) :578-590
[5]
SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]
RELATIVE ERROR AND VARIABILITY IN BLOOD-FLOW MEASUREMENTS WITH RADIOLABELED MICROSPHERES [J].
DOLE, WP ;
JACKSON, DL ;
ROSENBLATT, JI ;
THOMPSON, WL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (03) :H371-H378
[7]
VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[8]
MEASUREMENT OF ORGAN BLOOD HOW WITH COLORED MICROSPHERES IN THE RAT [J].
HAKKINEN, JP ;
MILLER, MW ;
SMITH, AH ;
KNIGHT, DR .
CARDIOVASCULAR RESEARCH, 1995, 29 (01) :74-79
[9]
EVALUATION OF NONRADIOACTIVE, COLORED MICROSPHERES FOR MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS [J].
HALE, SL ;
ALKER, KJ ;
KLONER, RA .
CIRCULATION, 1988, 78 (02) :428-434
[10]