Solution conformation of model peptides with the use of particle beam LC/FT-IR spectrometry and electrospray mass spectrometry

被引:13
作者
Venkateshwaran, TG
Stewart, JT [1 ]
Bishop, RT
de Haseth, JA
Bartlett, MG
机构
[1] Univ Athens, Coll Pharm, Dept Med Chem, Athens, GA 30602 USA
[2] Univ Georgia, Dept Chem, Athens, GA 30602 USA
关键词
angiotensin I; charge-state intensities; conformation; peptides; POMC-X;
D O I
10.1016/S0731-7085(97)00160-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solution conformations of the peptides angiotensin I (Ang I) and POMC-X (an octapeptide fragment of proopiomelanocortin) were investigated with the use of particle beam liquid chromatography/Fourier transform infrared (LC/FT-IR) spectrometry. Gradient elution high-performance liquid chromatography (HPLC) with mobile phases that contain acetonitrile, 2-propanol, 0.1% heptafluorobutyric acid (HFBA) and 0.1% trifluoroacetic acid (TFA) were used. The conformations of both peptides were studied in 0.9% sodium chloride injection USP, 5% dextrose in water injection USP and sterile water for Injection USP. Additional conformational studies over a pH range of 2-10, to a temperature of 75 degrees C and after a storage time of 24 h were investigated. The studies indicated that the two peptides do not behave similarly under identical conditions. It was observed that both Ang I and POMC-X had slightly different conformations in the various parenteral solutions. It was also shown that the conformation of Ang I changed with both pH and temperature while POMC-X was conformationally stable to both temperature and pH. The identity of the peptides and the conformationally sensitive charge-state intensities of the peptides were investigated with electrospray ionization mass spectrometry (ESI/MS). The combination of infrared and mass spectrometric data allowed a thorough estimation of solution effects on the conformations of the model peptides. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 25 条
[1]  
Aguilar M. I., 1991, HPLC PROTEINS PEPTID, P247
[2]   Electrospray ionization and matrix assisted laser desorption/ionization mass spectrometry: Powerful analytical tools in recombinant protein chemistry [J].
Andersen, JS ;
Svensson, B ;
Roepstorff, P .
NATURE BIOTECHNOLOGY, 1996, 14 (04) :449-457
[3]   CHARACTERIZATION BY TANDEM MASS-SPECTROMETRY OF STRUCTURAL MODIFICATIONS IN PROTEINS [J].
BIEMANN, K ;
SCOBLE, HA .
SCIENCE, 1987, 237 (4818) :992-998
[4]   Conformational effects on reversed-phase chromatography of proteins with particle beam LC/FT-IR spectrometry and free solution capillary electrophoresis [J].
Bishop, RT ;
Turula, VE ;
deHaseth, JA .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :4006-4014
[5]  
BISHOP RT, 1997, IN PRESS TECNIQUES P, V8
[6]   FORMULATION CONCERNS OF PROTEIN DRUGS [J].
CHEN, T .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1992, 18 (11-12) :1311-1354
[7]   PROBING CONFORMATIONAL-CHANGES IN PROTEINS BY MASS-SPECTROMETRY [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (24) :9012-9013
[8]  
DEHASETH JA, 1997, IN PRESS MIKROCHIM A
[9]   STRUCTURE OF SYNTHETIC POLYPEPTIDES [J].
ELLIOTT, A ;
AMBROSE, EJ .
NATURE, 1950, 165 (4206) :921-922
[10]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71