Rotational disorder in poly(p-phenylene terephthalamide) fibers by X-ray diffraction with a 100 nm beam

被引:36
作者
Roth, S
Burghammer, M
Janotta, A
Riekel, C
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] Walter Schottky Inst, D-85748 Garching, Germany
关键词
D O I
10.1021/ma021514g
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Single fibers of poly(p-phenylene terephthalamide) (PPTA; brand names Kevlar(x), where x = 29, 49, 149) have been scanned with an about 100 nm synchrotron radiation X-ray beam normal to the fiber axis. Models of rotational disorder of the crystalline domains are discussed based on Monte Carlo simulations of the spatial variation of the 110/200 reflection intensities. For Kevlar(149) the principal disorder appears to be a rotational domain-disorder across the fiber. The data suggest also the presence of a core and possibly a skin layer, which are both more disordered. Kevlar(29,49) appear to have the same type of layering but with different volume fractions. There is also some evidence for a volume fraction without rotational correlation, which might be related to a morphology formed at the onset of coagulation.
引用
收藏
页码:1585 / 1593
页数:9
相关论文
共 41 条
[41]   Comparison of the axial correlation lengths and paracrystalline distortion for Technora and Kevlar aromatic polyamide fibers [J].
Wu, TM ;
Blackwell, J .
MACROMOLECULES, 1996, 29 (17) :5621-5627