Constant vs automatic continuous positive airway pressure therapy - Home evaluation

被引:72
作者
d'Ortho, MP
Grillier-Lanoir, V
Levy, P
Goldenberg, F
Corriger, E
Harf, A
Lofaso, F
机构
[1] Hop Henri Mondor, Assistance Publ Hop Paris, Serv Physiol Explorat Fonct, F-94010 Creteil, France
[2] Hop Henri Mondor, Assistance Publ Hop Paris, INSERM, U492, F-94010 Creteil, France
[3] Hop Raymond Poincare, Assistance Publ Hop Paris, Serv Explorat Fonct, Garches, France
[4] CHU Grenoble, Dept Pneumol, Lab Sommeil, F-38043 Grenoble, France
[5] CHU Grenoble, CNRS, UMR 5525, F-38043 Grenoble, France
[6] Soc Nellcor Puritan Bennet, Villers Les Nancy, France
[7] ADEP Assistance, Suresnes, France
关键词
continuous positive airway pressure titration; obstructive sleep apnea;
D O I
10.1378/chest.118.4.1010
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To compare the efficacy and patient tolerance, compliance, and preference between auto-continuous positive airway pressure (CPAP) and constant CPAP. Design: Single-blinded, crossover, cohort study of consecutive patients with obstructive sleep apnea syndrome, with two treatment periods of 2 months each. Patients: Twenty-five patients (22 men, 3 women) with sleep apnea syndrome confirmed by ambulatory polysomnography. Measurements and interventions: After baseline polysomnography, patients underwent in-laboratory polysomnography for titration of constant CPAP. The order of treatment was randomly allocated, either auto-CPAP and then constant CPAP, or rice versa. The auto-CPAP pressure range was 6 to 16 cm H2O. At the end of each 2-month period, patients underwent a control ambulatory polysomnography and received a questionnaire oil subjective well-being and device evaluation. Duration of use was checked through CPAP device monitoring. Results: Rio differences were found in apnea/hypopnea index (constant CPAP, 9.7 +/- 1.9 events/h vs auto-CPAP, 10.6 +/- 9.3 events/h), awakening/arousal index (constant CPAP, 13.7 +/- 8.0 events/h vs auto-CPAP, 15.5 +/- 8.9 events/h), slow-wave sleep duration, nocturnal saturation, or complaint of daytime sleepiness. The mean pressure required was significantly lower during auto-CPAP than during constant CPAP (8.8 +/- 1.8 cm H2O vs 9.7 +/- 2.6 cm H2O, respectively). Patient tolerance, compliance, and duration of use were similar with both treatments. Conclusions: Auto-CPAP is as effective as constant CPAP. A wide pressure range for auto-CPAP can be used in all patients, suggesting that, in the future, use of a broad pressure range in the auto-CPAP mode could obviate the need for the titration night.
引用
收藏
页码:1010 / 1017
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 1992, SLEEP, V15, P174
[2]   Compliance with nasal CPAP can be improved by simple interventions [J].
Chervin, RD ;
Theut, S ;
Bassetti, C ;
Aldrich, MS .
SLEEP, 1997, 20 (04) :284-289
[3]   Cardiovascular aspects of obstructive sleep apnoea and their relevance to the assessment of the efficacy of nasal continuous positive airway pressure therapy [J].
Davies, RJO .
THORAX, 1998, 53 (05) :416-418
[4]   TREATMENT OF OBSTRUCTIVE SLEEP-APNEA WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE - PATIENT COMPLIANCE, PERCEPTION OF BENEFITS, AND SIDE-EFFECTS [J].
HOFFSTEIN, V ;
VINER, S ;
MATEIKA, S ;
CONWAY, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (04) :841-845
[5]   A NEW METHOD FOR MEASURING DAYTIME SLEEPINESS - THE EPWORTH SLEEPINESS SCALE [J].
JOHNS, MW .
SLEEP, 1991, 14 (06) :540-545
[6]   Use of conventional and self-adjusting nasal continuous positive airway pressure for treatment of severe obstructive sleep apnea syndrome - A comparative study [J].
Konermann, M ;
Sanner, BM ;
Vyleta, M ;
Laschewski, F ;
Groetz, J ;
Sturm, A ;
Zidek, W .
CHEST, 1998, 113 (03) :714-718
[7]   OBJECTIVE MEASUREMENT OF PATTERNS OF NASAL CPAP USE BY PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
KRIBBS, NB ;
PACK, AI ;
KLINE, LR ;
SMITH, PL ;
SCHWARTZ, AR ;
SCHUBERT, NM ;
REDLINE, S ;
HENRY, JN ;
GETSY, JE ;
DINGES, DF .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04) :887-895
[8]   Simplified diagnostic procedure for obstructive sleep apnoea syndrome: lower subsequent compliance with CPAP [J].
Krieger, J ;
Sforza, E ;
Petiau, C ;
Weiss, T .
EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (04) :776-779
[9]   NASAL CPAP CONTINUES TO IMPROVE SLEEP-DISORDERED BREATHING AND DAYTIME OXYGENATION OVER LONG-TERM FOLLOW-UP OF OCCLUSIVE SLEEP-APNEA SYNDROME [J].
LEECH, JA ;
ONAL, E ;
LOPATA, M .
CHEST, 1992, 102 (06) :1651-1655
[10]  
LEITER JC, 1985, AM REV RESPIR DIS, V132, P216