Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis

被引:143
作者
Baan, Jan, Jr. [1 ]
Yong, Ze Yie [1 ]
Koch, Karel T. [1 ]
Henriques, Jose P. S. [1 ]
Bouma, Berto J. [1 ]
Vis, Marije M. [1 ]
Cocchieri, Riccardo [1 ]
Piek, Jan J. [1 ]
de Mol, Bas A. J. M. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiol & Cardiothorac Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
BUNDLE-BRANCH BLOCK; ACUTE MYOCARDIAL-INFARCTION; HIGH-RISK PATIENTS; FOLLOW-UP; REPLACEMENT; STENOSIS; BIOPROSTHESIS; SURGERY; REQUIREMENT; EXPERIENCE;
D O I
10.1016/j.ahj.2009.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiac conduction disorders and requirement for permanent pacemaker implantation (PPI) are not uncommon after surgical aortic valve replacement and have important clinical implications. We aimed to investigate the incidence of cardiac conduction disorders after percutaneous aortic valve implantation (PAVI) and to identify possible clinical factors associated with their development. Methods We studied 34 patients (mean age 80 +/- 8 years, 18 male) who underwent PAVI with the CoreValve bioprosthesis (Corevalve Inc, Irvine, CA). Electrocardiographic evaluation was performed pre- and postprocedurally, and at 1-week and 1-month follow-up. Other clinical variables were obtained from the medical history, echocardiography, and angiography. Results After PAVI, 7 patients required PPI, all of whom developed total atrioventricular block within 3 days postprocedurally. A smaller left ventricular outflow tract diameter (20.3 +/- 0.5 vs 21.6 +/- 1.8 cm, P = .01), more left-sided heart axis (-20 degrees +/- 29 degrees vs 19 degrees +/- 36 degrees, P = .02), more mitral annular calcification (10 +/- 1 vs 5 +/- 4 mm, P = .008), and a smaller postimplantation indexed effective orifice area (0.86 +/- 0.20 vs 1.10 +/- 0.26 cm(2)/m(2), P = .04) were associated with PPI. The incidence of new left bundle-branch block (LBBB) was 65% and was associated with a deeper implantation of the prosthesis: 10.2 +/- 2.3 mm in the new-LBBB group versus 7.7 +/- 3.1 mm in the non-LBBB group (P = .02). Conclusions Percutaneous aortic valve implantation with the CoreValve prosthesis results in a high incidence of total atrioventricular block requiring PPI and new-onset LBBB. Preexisting disturbance of cardiac conduction, a narrow left ventricular outflow tract, and the severity of mitral annular calcification predict the need for permanent pacing, whereas the only factor shown to be predictive for new-onset LBBB is the depth of prosthesis implantation. (Am Heart J 2010; 159:497-503.)
引用
收藏
页码:497 / 503
页数:7
相关论文
共 23 条
[1]   Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving™ system [J].
Berry, Colin ;
Asgar, Anita ;
Lamarche, Yoan ;
Marcheix, Bertrand ;
Couture, Pierre ;
Basmadjian, Arsene ;
Ducharme, Anique ;
Laborde, Jean-Claude ;
Cartier, Raymond ;
Bonan, Raoul .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) :610-616
[2]  
BOUGHALEB D, 1994, ARCH MAL COEUR VAISS, V87, P925
[3]   Early Conduction Disorders Following Percutaneous Aortic Valve Replacement [J].
Calvi, Valeria ;
Puzzangara, Euglena ;
Pruiti, Giusi Paola ;
Conti, Sergio ;
Di Grazia, Angelo ;
Ussia, Gian Paolo ;
Capodanno, Davide ;
Tamburino, Corrado .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S126-S130
[4]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[5]   Cardiac pacing following surgery for acquired heart disease [J].
DelRizzo, DF ;
Nishimura, S ;
Lau, C ;
Sever, J ;
Goldman, BS .
JOURNAL OF CARDIAC SURGERY, 1996, 11 (05) :332-340
[6]   Prognostic significance of newly acquired bundle branch block after aortic valve replacement [J].
El-Khally, Z ;
Thibault, B ;
Staniloae, C ;
Theroux, P ;
Dubuc, M ;
Roy, D ;
Guerra, P ;
Macle, L ;
Talajic, M .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (08) :1008-1011
[7]   The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery [J].
Elahi, Maqsood ;
Usmaan, Khalid .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (02) :113-118
[8]   Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement [J].
Erdogan, HB ;
Kayalar, N ;
Ardal, H ;
Omeroglu, SN ;
Kirali, K ;
Guler, M ;
Akinci, E ;
Yakut, C .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (03) :211-215
[9]   Permanent cardiac pacing after a cardiac operation: Predicting the use of permanent pacemakers [J].
Gordon, RS ;
Ivanov, J ;
Cohen, G ;
Ralph-Edwards, AL .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1698-1704
[10]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76