Polymer gel dosimetry using x-ray computed tomography: a feasibility study

被引:163
作者
Hilts, M
Audet, C
Duzenli, C
Jirasek, A
机构
[1] British Columbia Canc Agcy, Vancouver Canc Ctr, Vancouver, BC V5Z 4E6, Canada
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
10.1088/0031-9155/45/9/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N-CT-dose response) and the reproducibility of the response are investigated, and the use of CT to analyse PAG is compared with MRI. Experiments were conducted using two 1.5 1 cylindrical PAG phantoms (3% acrylamide, 3% bis and 5% gelatin by weight), one irradiated with Four intersecting 10 MV photon beams and the other with 10 sets of 6 MV parallel opposed circular radiosurgery fields. The final imaging protocol involves using optimum CT parameters (120 kVp and 200 mAs for our GE HiSpeed CT/i(R) scanner), image averaging and background subtraction. The N-CT-dose response is reproducible, linear up to 800-1000 cGy and is relatively insensitive to the gel temperature during imaging. The dose resolution is similar to 50 cGy for an image thickness of 10 mm. Despite the low dose resolution, preliminary results indicate that this CT technique provides accurate localization of high dose gradients such as those observed in stereotactic radiosurgery. Thus, given the availability and speed of CT scanners, the technique has the potential to be a valuable and practical 3D dose verification tool in radiation therapy.
引用
收藏
页码:2559 / 2571
页数:13
相关论文
共 31 条
[1]  
Audet C., 1995, THESIS MCGILL U MONT
[2]   Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry [J].
Baldock, C ;
Rintoul, L ;
Keevil, SF ;
Pope, JM ;
George, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3617-3627
[3]   Uncertainty analysis in polymer gel dosimetry [J].
Baldock, C ;
Murry, P ;
Kron, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :N243-N246
[4]  
BALDOCK C, 1999, DOSGEL 99, P99
[5]  
Brooks R. A., 1980, MED PHYSICS CT ULTRA, P37
[6]  
CURRY TS, 1990, CHRISTENSENS PHYSICS
[7]   Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer [J].
De Deene, Y ;
De Wagter, C ;
Van Duyse, B ;
Derycke, S ;
De Neve, W ;
Achten, E .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :283-291
[8]   NON-INVASIVE THERMOMETRY WITH A CLINICAL X-RAY CT SCANNER [J].
FALLONE, BG ;
MORAN, PR ;
PODGORSAK, EB .
MEDICAL PHYSICS, 1982, 9 (05) :715-721
[9]  
GORE J C, 1984, Magnetic Resonance Imaging, V2, P244, DOI 10.1016/0730-725X(84)90033-X
[10]   MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING [J].
GORE, JC ;
KANG, YS ;
SCHULZ, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1189-1197