Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments

被引:25
作者
Lazebnik, RS
Lancaster, TL
Breen, MS
Lewin, JS
Wilson, DL
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
image guided therapy; interventional MRI; medical image processing; radio-frequency thermal ablation; volume registration;
D O I
10.1109/TMI.2003.812246
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We created a method for three-dimensional (3-D) registration of medical images (e.g., magnetic resonance imaging (MRI) or computed tomography) to images of physical tissue sections or to other medical images and evaluated its accuracy. Our method proved valuable for evaluation of animal model experiments on interventional-MRI guided thermal ablation and on a new localized drug delivery system. The method computes an optimum set of rigid body registration parameters by minimization of the Euclidean distances between automatically chosen correspondence points, along manually selected fiducial needle paths, and optional point landmarks, using the iterative closest point algorithm. For numerically simulated experiments, using two needle paths over a range of needle orientations, mean voxel displacement errors depended mostly on needle localization error when the angle between needles was at least 20degrees. For parameters typical of our in vivo experiments, the mean voxel displacement error was <0.35 mm. In addition, we determined that the distance objective function was a useful diagnostic for predicting registration quality. To evaluate the registration quality of physical specimens, we computed the misregistration for a needle not considered during the optimization procedure. We registered an ex vivo sheep brain MR volume with another MR volume and tissue section photographs, using various combinations of needle and point landmarks. Mean registration error was always less than or equal to0.54 nun for MR-to-MR registrations and less than or equal to0.52 mm for MR to tissue section registrations. We also applied the method to correlate MR volumes of radio-frequency induced thermal ablation lesions with actual tissue destruction. In this case, in vivo rabbit thigh volumes were registered to photographs of ex vivo tissue sections using two needle paths. Mean registration errors were between 0.7 and 1.36 nun over all rabbits, the largest error less than two MR voxel widths. We conclude that our method provides sufficient spatial correspondence to facilitate comparison of 3-D image data with data from gross pathology tissue sections and histology.
引用
收藏
页码:653 / 660
页数:8
相关论文
共 18 条
[1]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[2]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[3]  
BREEN MS, IN PRESS J MAGN RESO
[4]   Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging [J].
Chung, YC ;
Duerk, JL ;
Lewin, JS .
INVESTIGATIVE RADIOLOGY, 1997, 32 (08) :466-474
[5]   Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment - Preliminary ex vivo and in vivo results [J].
Goldberg, SN ;
Gazelle, GS ;
Debatin, JF .
INVESTIGATIVE RADIOLOGY, 1997, 32 (11) :671-678
[6]  
Jolesz FA, 2001, J MAGN RESON IMAGING, V13, P69, DOI 10.1002/1522-2586(200101)13:1<69::AID-JMRI1011>3.0.CO
[7]  
2-2
[8]   Biopsy needle susceptibility artifacts [J].
Ladd, ME ;
Erhart, P ;
Debatin, JF ;
Romanowski, BJ ;
Boesiger, P ;
McKinnon, GC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :646-651
[9]   Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system [J].
Lewin, JS ;
Petersilge, CA ;
Hatem, SF ;
Duerk, JL ;
Lenz, G ;
Clampitt, ME ;
Williams, ML ;
Kaczynski, KR ;
Lanzieri, CF ;
Wise, AL ;
Haaga, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (06) :1593-1601
[10]   Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation [J].
Lewin, JS ;
Duerk, JL ;
Jain, VR ;
Petersilge, CA ;
Chao, CP ;
Haaga, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1337-1345