Comparison of phased-array and body coils for MR imaging of liver

被引:7
作者
Schwartz, LH
Panicek, DM
Thomson, E
Herman, SK
Shah, GV
Heelan, RT
Fong, Y
Blumgart, LH
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT SURG,NEW YORK,NY 10021
[2] CORNELL UNIV,COLL MED,NEW YORK,NY
关键词
D O I
10.1016/S0009-9260(97)80152-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aims and Objectives: To compare liver lesion conspicuity using torso phased-array (TPA) and body coils with two pulse sequences. Methods: Sixty patients with 125 focal hepatic lesions underwent T2-weighted fast spin-echo (T2-FSE) and fast multiplanar inversion recovery (FMPIR) imaging with a standard body coil and with a TPA coil. The first 30 patients were scanned identically in both coils with four acquisitions; the second 30 were scanned with four acquisitions in the body coil and two in the TPA coil. Results: Liver-lesion contrast-to-noise (C/N) was significantly higher for the TPA coil both with four acquisitions (P < 0.001) and with two acquisitions (P < 0.002) using FMPIR, compared to with four acquisitions in the body coil. Liver-lesion CIN for T2-FSE was equivalent in both coils. Liver-lesion CIN was significantly higher (P < 0.01) for FMPIR than T2-FSE both in the body coil and in the TPA coil. Conclusion : Liver-lesion CIN was significantly higher using the TPA coil rather than the body coil, Imaging time can be reduced by decreasing the number of acquisitions with the TPA coil.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 19 条
[1]  
ANZAI Y, 1992, AM J NEURORADIOL, V13, P879
[2]   FOCAL HEPATIC-LESIONS - DIFFERENTIATION WITH MR-IMAGING AT 0.5 T [J].
BROWN, JJ ;
LEE, JM ;
LEE, JKT ;
VANLOM, KJ ;
MALCHOW, SC .
RADIOLOGY, 1991, 179 (03) :675-679
[3]   MR IMAGING OF THE LIVER USING SHORT TI INVERSION RECOVERY SEQUENCES [J].
BYDDER, GM ;
STEINER, RE ;
BLUMGART, LH ;
KHENIA, S ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (06) :1084-1089
[4]   MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION [J].
CAMPEAU, NG ;
JOHNSON, CD ;
FELMLEE, JP ;
RYDBERG, JN ;
BUTTS, RK ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 195 (03) :769-776
[5]   SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[6]   SHORT TI INVERSION-RECOVERY IMAGING OF THE LIVER - PULSE-SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO IMAGING [J].
DOUSSET, M ;
WEISSLEDER, R ;
HENDRICK, RE ;
STARK, DD ;
FRETZ, CJ ;
ELIZONDO, G ;
HAHN, PF ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1989, 171 (02) :327-333
[7]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[8]   FAST SPIN-ECHO MR-IMAGING OF THE ABDOMEN - CONTRAST OPTIMIZATION AND ARTIFACT REDUCTION [J].
LOW, RN ;
HINKS, RS ;
ALZATE, GD ;
SHIMAKAWA, A .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :637-645
[9]   ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING [J].
LOW, RN ;
FRANCIS, IR ;
SIGETI, JS ;
FOO, TKF .
RADIOLOGY, 1993, 186 (03) :803-811
[10]   T2-WEIGHTED MR-IMAGING OF THE UPPER PART OF THE ABDOMEN - SHOULD FAT-SUPPRESSION BE USED ROUTINELY [J].
LU, DSK ;
SAINI, S ;
HAHN, PF ;
GOLDBERG, M ;
LEE, MJ ;
WEISSLEDER, R ;
GERARD, B ;
HALPERN, E ;
CATS, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (05) :1095-1100