Improved reconstruction for MR spectroscopic imaging

被引:22
作者
Bao, Yufang [1 ]
Maudsley, Andrew A. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Radiol, MR Ctr, Miami, FL 33136 USA
关键词
brain metabolite images; image reconstruction; magnetic resonance spectroscopic imaging (MRSI);
D O I
10.1109/TMI.2007.895482
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Sensitivity limitations of in vivo magnetic resonance spectroscopic imaging (MRSI) require that the extent of spatial-frequency (k-space) sampling be limited, thereby reducing spatial resolution and increasing the effects of Gibbs ringing that is associated with the use of Fourier transform reconstruction. Additional problems occur in the spectral dimension, where quantitation of individual spectral components is made more difficult by the typically low signal-to-noise ratios, variable lineshapes, and baseline distortions, particularly in areas of significant magnetic field inhomogeneity. Given the potential of in vivo MRSI measurements for a number of clinical and biomedical research applications, there is considerable interest in improving the quality of the metabolite image reconstructions. In this report, a reconstruction method is described that makes use of parametric modeling and MRI-derived tissue distribution functions to enhance the MRSI spatial reconstruction. Additional preprocessing steps are also proposed to avoid difficulties associated with image regions containing spectra of inadequate quality, which are commonly present in the in vivo MRSI data.
引用
收藏
页码:686 / 695
页数:10
相关论文
共 32 条
[1]  
Angelie E, 2001, AM J NEURORADIOL, V22, P119
[2]  
[Anonymous], 2002, Brain Mapping: The Methods
[3]   Natural linewidth chemical shift imaging (NL-CSI) [J].
Bashir, Adil ;
Yablonskiy, Dmitriy A. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :7-18
[4]   PARALLEL ALGORITHMS FOR MAXIMUM-LIKELIHOOD NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY [J].
CHEN, SC ;
SCHAEWE, TJ ;
TEICHMAN, RS ;
MILLER, MI ;
NADEL, SN ;
GREENE, AS .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 102 (01) :16-23
[5]   Design and construction of a realistic digital brain phantom [J].
Collins, DL ;
Zijdenbos, AP ;
Kollokian, V ;
Sled, JG ;
Kabani, NJ ;
Holmes, CJ ;
Evans, AC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :463-468
[6]   The filtering approach to solvent peak suppression in MRS: A critical review [J].
Coron, A ;
Vanhamme, L ;
Antoine, JP ;
Van Hecke, P ;
Van Huffel, S .
JOURNAL OF MAGNETIC RESONANCE, 2001, 152 (01) :26-40
[7]  
Friston KJ, 1995, HUMAN BRAIN MAPPING, V2, P165
[8]   BAYESIAN RECONSTRUCTIONS FROM EMISSION TOMOGRAPHY DATA USING A MODIFIED EM ALGORITHM [J].
GREEN, PJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (01) :84-93
[9]   Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation [J].
Haupt, CI ;
Schuff, N ;
Weiner, MW ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :678-687
[10]  
HU X, 1992, P ISMRM, P4253